Device parameters and interfaces
Leuze electronic
BPS 34
63
TNT 35/7-24V
8.1.7.9 Module 9: Controller
Description
The Control module manages timing of the position calculation by starting and stopping the
decoding. Control is performed depending on certain events such as the switching input,
time functions or PROFIBUS output bits. Using parameters, the events which influence the
states are determined.
Parameter
Hex coding of module 9 "Control"
The value listed in the table shows the hex coding of the default settings.
Parameter
Description
Rel.
addr.
Data
type
Value range
Default
Unit
CR to
module
Measure-
ment start
mode
The start mode determines by
which event the position meas-
urement is started.
0
unsign
8
0: Deactivated
1: After initialisation
2: By event:
Switching input or start event
by setting output bit 0.0
1
–
7 g
Measure-
ment stop
mode
The measurement stop mode
determines after which event
the position measurement is
stopped.
1
unsign
8
0: No function
1: After valid measurement
result
2: After timeout (stop time-
out)
3: After timeout with retrigger
(stop timeout) by setting out-
put bit 0.0 or by the switching
input
4: By stop event or by set-
ting output bit 0.1
or by the
switching input (the switching
input must be programmed
for this purpose)
5: By an error
4
–
7 g
Stop time-
out in [ms]
Time for stop timeout
2
unsign
16
0 … 65’535
10’000
ms
–
Parameter length: 4 byte
a
b
c
Internal ad
dress of module 9
Measurement star
t mode
ad
dr
ess 0
Measurement stop mode
ad
dr
ess 1
Stop timeout
ad
dr
ess 2
03
01
04
27 10