Device parameters and interfaces
Leuze
electronic
56
BPS 34
Leuze electronic
8.1.7.5 Module 5: Offset value
Notice!
Underlined in the CR column are the modules which must be activated in addition to the cur-
rent module.
Description
This module adds an offset value to the tape value.
Parameter
Notice!
If module 3 "Static preset" or module 4 "Dynamic preset" is activated and, as a result, a new
value assigned to the tape value, the offset function no longer affects the position value. The
offset is not reactivated until the preset function (static and dynamic) is cancelled. The offset
value is entered in mm. When entering the offset value, the scaling in module 6 must be tak-
en into account.
Hex coding of module 5 "Offset value"
The value listed in the table shows the hex coding of the default settings.
Input data
none
Output data
none
Parameter
Description
Rel.
addr.
Data
type
Value range
Default
Unit
CR to
module
Offset
value in
[mm]
Offset value added to tape value
0
sign32 -10’000’000 … 10’000’000
0
mm
1
Parameter length: 4 byte
a
Internal ad
dress
of module 5
Offset v
a
lue
09
00 00 00 00