Device parameters and interfaces
Leuze
electronic
68
BPS 34
Leuze electronic
8.1.7.13 Module 12: Status
Notice!
Underlined in the CR column are the modules which must be activated in addition to the cur-
rent module.
Description
This module supplies various BPS 34 status information to the PROFIBUS master.
Parameter
none
Input data
Output data
none
Input data
Description
Rel.
addr.
Data
type
Value range
Default
Unit
CR to
module
Measure-
ment error
Indicates that no valid integra-
tion value could be determined
(measurement value prepara-
tion module).
0.0
Bit
0: OK
1: Error
0
–
–
Range sta-
tus
Indicates that measurement
range has been exceeded
(measurement value acquisi-
tion module)
0.1
Bit
0: OK, within measurement
range
1: Measurement range
exceeded
0
–
10
Preset
active
Indicates a position-value output
with active static preset or
dynamic preset (Preset module)
0.2
Bit
0: No preset active
1: Preset active
0
–
3a
4c
Preset
teach
Toggle bit, changes during the
teach event for the static and
dynamic preset value (Preset
module)
0.3
Bit
0,1: Dyn. preset teach
0
–
3a
4c
Position
limit value
status 1
(static or
dynamic)
Indicates that limit value 1 has
been exceeded (measurement
value monitoring module).
0.4
Bit
0: No limit value violation
1: Value greater than limit
0
–
14d
16d
Position
limit value
status 2
(static or
dynamic)
Indicates that limit value 2 has
been exceeded (measurement
value monitoring module).
0.5
Bit
0: No limit value violation
1: Value greater than limit
0
–
15d
17d
Standby
status
Signals the standby status
(Control module)
0.7
Bit
0: BPS active
1: BPS in standby
0
–
9d
Input data length: 1 byte
a
b
c
d
e
f
g