Device parameters and interfaces
Leuze
electronic
70
BPS 34
Leuze electronic
Input data
Output data
Notice!
With "MinMax reset", the input data are reset to 155812h.
With this module, the settings for the Preset (module 3), Offset (module 5) and Scaling
(module 6) modules must be taken into account.
Input data
Description
Rel.
addr.
Data
type
Value range
Default
Unit
CR to
module
Min position
Minimum position for
detected period.
0
sign32 -10’000’000 … 10’000’000
0
Reset:
2’147’483’647
scaled
–
Max position
Maximum position for
detected period.
4
sign32 -10’000’000 … 10’000’000
0
Reset:
-2’147’483’647
scaled
–
Input data length: 8 byte
c
d
Output data
Description
Rel.
addr.
Data
type
Value range
Default
Unit
CR to
module
MinMax reset
Signal for resetting
extreme values
0.0
Bit
0 -> 1: Reset
0
–
7
Output data length: 8 byte
e