EtherNet/IP interface
83
AMS 358
i
Leuze electronic
9.7.8.4
Preset value + control
Instance 120, attribute 3
Output assembly, length 8 bytes
Leuze-specific assembly
Byte 0 - byte 3: preset value
Byte 4: preset control
Byte 5 - Byte 7: reserved
Notice!
Negative values are displayed in two's complement.
Path
Designation
Size
in bit
Data type
Default
(dec)
Min
(dec)
Max
(dec)
Access
Cl.
Inst.
Attr.
4
120
3
Preset value
32
DINT
-
-21474836480
+2147483648
Set
Preset control
8
Byte
-
0
3
Set
Reserved
24
DINT
0
-
-
Get
Inst.
Byte
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
120
0
Preset value (low byte)
1
Preset value
2
Preset value
3
Preset value (high byte)
4
0
0
0
0
0
0
Preset reset
1 = ON
0 = OFF
Preset teach
1 = ON
0 = OFF
5
0
0
0
0
0
0
0
0
6
0
0
0
0
0
0
0
0
7
0
0
0
0
0
0
0
0