EtherNet/IP interface
Leuze electronic
AMS 358
i
64
TNT
35/7-2
4
V
Notice!
Negative values are displayed in two's complement.
9.7.2.2
Position sensor type
Attribute 11
Specifies the encoder with ID 8
d
defined via CIP as absolute measuring linear encoder.
9.7.2.3
Direction counting
Attribute 12
Defines whether the measured distance value increases (positive counting direction) or
decreases (negative counting direction) with increasing distance.
0 = positive counting direction
1 = negative counting direction
9.7.2.4
Position format
Attribute 15
Configures the position format as well as the resolution. The EDS file makes available the
following parameters:
Notice!
If the position format is changed from metric to inch, the velocity format is automatically,
internally converted to hundredths of an inch per second. If the position format is changed
from inch to metric, the velocity format is automatically, internally converted to millimeters
per second.
9.7.2.5
Velocity value
Attribute 24
Read velocity value.
Dec. value
Hex. Value
Unit
Format
8706
0x22 02
Centimeter [cm]
Metric
8707
0x22 03
Millimeter [mm]
8708
0x22 04
Micrometer [μm]
2048
0x08 00
Free resolution [mm]
2049
0x08 01
Tenth of millimeter [mm/10]
2050
0x08 02
Hundredths of millimeter [mm/100]
2051
0x08 03
Hundredths of inch [in/100]
Inch
2052
0x08 04
Free resolution [in/100]
Attr.
Byte
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
24
0
Velocity value (low byte)
1
Velocity value
2
Velocity value
3
Velocity value (high byte)