EtherNet/IP interface
73
AMS 358
i
Leuze electronic
9.7.5
Class 103 Switching inputs/outputs
Class 103, instance 1 describes I/O 1 (PIN 2/M 12 Power)
Class 103, instance 2 describes I/O 2 (PIN 4/M 12 Power)
Object class 103 = 67
H
Service:
• Get_Attribute_Single
• Set_Attribute_Single
9.7.5.1
Definition of input/output
Instance 1, attribute 1 (PIN 2/M 12 Power)
Instance 2, attribute 1 (PIN 4/M 12 Power)
Path
Designation
Size
in bit
Data type
Default
(dec)
Min
(dec)
Max
(dec)
Access
Cl.
Inst.
Attr.
103
1
1
Function I/O (input/output)
8
BYTE
1
0
1
Set
2
Activation (high/low active)
8
BYTE
0
0
1
Set
3
Output function
16
WORD
192
0
511
Set
4
Input function
8
BYTE
0
0
3
Set
5
Status (input/output)
8
BYTE
0
0
1
Get
6
Activation output
8
BYTE
0
0
1
Set
103
2
1
Function I/O (input/output)
8
BYTE
1
0
1
Set
2
Activation (high/low active)
8
BYTE
0
0
1
Set
3
Output function
16
WORD
56
0
511
Set
4
Input function
8
BYTE
0
0
3
Set
5
Status (input/output)
8
BYTE
0
0
1
Get
6
Activation output
8
BYTE
0
0
1
Set