EtherNet/IP interface
Leuze electronic
AMS 358
i
80
TNT
35/7-2
4
V
If the value is exceeded or not met, the limit value status (attribute 7) and, if applicable, the
output are set via class 103, instance 1 or 2, attribute 3 depending on the selected switching
mode.
0 = direction independent
1 = direction dependent
9.7.7.4
Velocity limit value - velocity limit value
Attribute 4
The limit value configured in attribute 3 is compared to the measured ACTUAL velocity. The
entry is made in mm/s or inch/100 s.
9.7.7.5
Velocity limit value - velocity hysteresis
Attribute 5
Attribute 4 describes the switching hysteresis for the value entered in attribute 3 to prevent
bouncing of the signal. The entry is made in mm/s or inch/100 s.
9.7.7.6
Velocity limit value - limit value range start
Attribute 6
The limit value is monitored beginning at this position. The value is specified in mm or inch/100.
If the values for range start and range end are the same, velocity monitoring is not activated.
9.7.7.7
Velocity limit value - limit value range end
Attribute 7
The limit value is monitored beginning at this position. The value is specified in mm or inch/100.
If the values for range start and range end are the same, velocity monitoring is not activated.
9.7.7.8
Velocity limit value - limit value status
Attribute 8
The attribute signals that the configured limit values have been exceeded.
0 = limit values maintained
1 = limit values exceeded.
9.7.7.9
Velocity limit value - limit value comparison
Attribute 9
The attribute indicates whether the respective velocity limit value is compared with the
configured limit value.
0 = comparison inactive
1 = comparison active