Fast commissioning / operating principle
Leuze electronic
AMS 358
i
14
TNT
35/7-2
4
V
Attention!
If the config assembly is not adapted, the AMS 358
i
displays a corresponding behavior acc.
to the parameters preset with 0.
ª
Switch the control to offline mode.
ª
Double-click
Controller Tags
to edit the configuration assembly.
The configuration assembly can be recognized by the index "C" appended to the device
name.
Parameter entry is performed as described in
.
Attention!
Activation of the config assembly as described above necessitates value entry in the
corresponding parameter memory locations. When using the configuration assembly, the
default parameters must also be entered in the corresponding memory locations (see also
chapter 9.7.8.5.).
After all of the parameters relevant to the AMS 358
i
are entered, the control is switched to
"online" and the project is downloaded again.
Using explicit messaging services
Explicit messaging services (e.g., "get attributes …, set attribute …, and others) can be used
to acyclically access all data of the AMS 358
i
Attention!
If parameters are changed via explicit messaging services while simultaneously activating a
configuration assembly, the changed parameters must subsequently be entered in the
configuration assembly.