![Leuze electronic AMS 358i Manual Download Page 73](http://html1.mh-extra.com/html/leuze-electronic/ams-358i/ams-358i_manual_1883975073.webp)
EtherNet/IP interface
Leuze electronic
AMS 358
i
70
TNT
35/7-2
4
V
9.7.2.25 Laser diode laser status
Attribute 109
The attribute signals the status of the laser diode.
0 = laser diode on
1 = laser diode off
9.7.2.26 Laser diode laser control
Attribute 110
The laser can be switched on and off via this attribute.
1 = laser diode on
0 = laser diode off
9.7.3
Class 100 Display configuration
Object class 100 = 64
H
Service:
• Get_Attribute_Single
• Set_Attribute_Single
9.7.3.1
Language selection
Attribute 1
The attribute can be used to configure the language that appears in the display.
The following table provides information on the languages available for selection.
9.7.3.2
Password protection
Attribute 2
The attribute activates password protection.
1 = password protection active
0 = password protection inactive
Path
Designation
Size
in bit
Data type
Default
(dec)
Min
(dec)
Max
(dec)
Access
Cl.
Inst.
Attr.
100
1
1
Language selection
8
BYTE
0
0
16
Set
2
Password protection
8
BYTE
0
0
1
Set
3
Password
16
UINT
0
0
9.999
Set
4
Illumination
8
BYTE
0
0
1
Set
5
Contrast
8
BYTE
1
0
3
Set
6
Extended heating control
8
BYTE
0
0
1
Set
Language
Value
English
0
German
1
Italian
2
Spanish
3
French
4