Diagnostics and troubleshooting
Leuze electronic
AMS 358
i
90
TNT
35/7-2
4
V
10.2.1
Power LED
See also chapter 8.2.2.
10.3
Interface errors
10.3.1
Net LED
10.4
Status display in the display of the AMS 358
i
Error
Possible error cause
Measure
PWR LED "OFF"
No supply voltage connected
Check supply voltage.
Hardware error
Send in device.
PWR-LED "flashes red"
Light beam interruption
Check alignment.
Plausibility error
Traverse rate >10m/s.
PWR-LED "static red"
Hardware error
For error description, see display,
It may be necessary to send in the device.
Table 10.1:
General causes of errors
Error
Possible error cause
Measure
Net LED "OFF"
Power off on AMS 358
i
Check supply voltage.
Net LED "flashes red"
Time-out in bus communication
AMS 358
i
configured in the control.
Net LED "static red"
Double IP address assignment
Check IP addresses.
Net LED "flashes green"
No communication can be established
Check configuration in the control.
The AMS 358
i
is not listed in the scan list of the master
Net LED "flashes green/
red"
The AMS 358i is not assigned to any master
Check configuration in the control.
No EtherNet/IP communication present
Table 10.2:
Bus error
Display
Possible error cause
Measure
PLB
(implausible measurement
values)
Laser beam interruption
Laser spot must always be incident on the reflector.
Laser spot outside of reflector
Traverse rate < 10 m/s?
Measurement range for maximum distance
exceeded
Restrict traversing path or select AMS with larger
measurement range.
Velocity greater than 10 m/s
Reduce velocity.
Ambient temperature far outside of the permissible
range (TMP display; PLB)
Select AMS with heating or ensure cooling.
ATT
(insufficient received signal
level)
Reflector soiled
Clean reflector or glass lens.
Glass lens of the AMS soiled
Performance reduction due to snow, rain, fog, con-
densing vapor, or heavily polluted air (oil mist, dust)
Optimize usage conditions.
Laser spot only partially on the reflector
Check alignment.
Protective foil on the reflector
Remove protective foil from reflector.