![Leuze electronic AMS 358i Manual Download Page 88](http://html1.mh-extra.com/html/leuze-electronic/ams-358i/ams-358i_manual_1883975088.webp)
EtherNet/IP interface
85
AMS 358
i
Leuze electronic
22
103 / 1 / 2
Activation (high/low active)
-- -- -- -- -- -- -- 0
00
23
103 / 1 / 3
Function output low byte
1
1
0
0
0
0 -- --
C0
24
Function outputhigh byte
-- -- -- -- -- -- -- 0
00
25
103 / 1 / 4
Function input
-- -- -- -- -- -- 0
0
00
26
103 / 2 / 1
Function I/O (input or output)
-- -- -- -- -- -- -- 1
01
27
103 / 2 / 2
Activation (high/low active)
-- -- -- -- -- -- -- 0
00
28
103 / 2 / 3
Function output low byte
0
0
1
1
1
0
0
0
38
29
Function outputhigh byte
0
0
0
0
0
0
0
0
00
30
103 / 2 / 4
Function input
-- -- -- -- -- -- 0
0
00
31
104 / 1 / 1
Position value in the case of error
-- -- -- -- -- -- -- 1
01
32
104 / 1 / 2
Suppress status PLB (position error)
-- -- -- -- -- -- -- 1
01
33
104 / 1 / 3
Error delay (position error)
-- -- -- -- -- -- -- 1
01
34
104 / 1 / 4
Error delay time positionlow byte
0
1
1
0
0
1
0
0
64
35
Error delay time positionhigh byte
0
0
0
0
0
0
0
0
00
36
104 / 1 / 5
Velocity value in case of failure
-- -- -- -- -- -- -- 1
01
37
104 / 1 / 6
Suppress status (velocity error)
-- -- -- -- -- -- -- 1
01
38
104 / 1 / 7
Error delay (velocity error)
-- -- -- -- -- -- -- 1
01
39
104 / 1 / 8
Error delay time velocitylow byte
1
1
0
0
1
0
0
0
C8
40
Error delay time velocityhigh byte
0
0
0
0
0
0
0
0
00
41
105 / 1 / 1
Activation velocity monitoring
-- -- -- -- -- -- -- 0
00
42
105 / 1 / 2
Switch type limit value exceeded/not met
-- -- -- -- -- -- -- 0
00
43
105 / 1 / 3
Direction selection direction independent/dependent
-- -- -- -- -- -- -- 0
00
44
105 / 1 / 4
Velocity limit value low byte
0
0
0
0
0
0
0
0
00
45
Velocity limit value high byte
0
0
0
0
0
0
0
0
00
46
105 / 1 / 5
Velocity hysteresis low byte
0
1
1
0
0
1
0
0
64
47
Velocity hysteresis high byte
0
0
0
0
0
0
0
0
00
48
105 / 1 / 6
Limit value range start low byte
0
0
0
0
0
0
0
0
00
49
Limit value range start
0
0
0
0
0
0
0
0
00
50
Limit value range start
0
0
0
0
0
0
0
0
00
51
Limit value range start high byte
0
0
0
0
0
0
0
0
00
52
105 / 1 / 7
Limit value range end low byte
0
0
0
0
0
0
0
0
00
53
Limit value range end
0
0
0
0
0
0
0
0
00
54
Limit value range end
0
0
0
0
0
0
0
0
00
55
Limit value range endhigh byte
0
0
0
0
0
0
0
0
00
56
105 / 2 / 1
Activation velocity monitoring
-- -- -- -- -- -- -- 0
00
57
105 / 2 / 2
Switch type limit value exceeded/not met
-- -- -- -- -- -- -- 0
00
58
105 / 2 / 3
Direction selection direction independent/dependent
-- -- -- -- -- -- -- 0
00
59
105 / 2 / 4
Velocity limit value low byte
0
0
0
0
0
0
0
0
00
60
Velocity limit value high byte
0
0
0
0
0
0
0
0
00
61
105 / 2 / 5
Velocity hysteresis low byte
0
1
1
0
0
1
0
0
64
62
Velocity hysteresis high byte
0
0
0
0
0
0
0
0
00
63
105 / 2 / 6
Limit value range start low byte
0
0
0
0
0
0
0
0
00
64
Limit value range start
0
0
0
0
0
0
0
0
00
65
Limit value range start
0
0
0
0
0
0
0
0
00
66
Limit value range start high byte
0
0
0
0
0
0
0
0
00
67
105 / 2 / 7
Limit value range end low byte
0
0
0
0
0
0
0
0
00
68
Limit value range end
0
0
0
0
0
0
0
0
00
69
Limit value range end
0
0
0
0
0
0
0
0
00
70
Limit value range end high byte
0
0
0
0
0
0
0
0
00
71
105 / 3 / 1
Activation velocity monitoring
-- -- -- -- -- -- -- 0
00
72
105 / 3 / 2
Switch type limit value exceeded/not met
-- -- -- -- -- -- -- 0
00
Byte
Cross-reference
address
Class/Instance/
Attribute
Function
Bit assignment (default)
Default
(hex)
7
6
5
4
3
2
1
0