: Factory settin
g
s
Adjustment range : DISABLED (0), 50Hz HIGH (1), 60Hz
HIGH (2),
50Hz LOW Trq (3), 60Hz LOW Trq (4),
Mot.EXCLUDED (5)
Factory setting
: DISABLED (0)
DISABLED (0): No return to factory settin
g
s.
50 Hz HIGH (1):
Used to set the drive to factory settings with
a 400 V/50 Hz motor and a high overload (heavy duty).
60Hz HIGH (2):
Used to set the drive to factory settings with
a 460 V/60 Hz motor and a high overload (heavy duty).
50Hz LOW Tr
q
(3):
Used to set the drive to factory settings
with a 400 V/50 Hz motor and a low overload (normal duty).
60Hz LOW Tr
q
(4):
Used to set the drive to factory settings
with a 460 V/60 Hz motor and a low overload (normal duty).
Mot.EXCLUDED (5):
Used to set the drive to factory settings
with the exception of parameters linked to the motor.
Function 5 is not available in the current version.
Note:
The factory settings for
00.06
and
00.07
according to
00.45
are listed in section 5.6.3.
: Preset reference 1
Adjustment range : ±
00.02
rpm
Factory setting
: 0
Used to define preset reference Pr1.
: Preset reference 2
Adjustment range : ±
00.02
rpm
Factory setting
: 0
Used to define preset reference Pr2.
: Preset reference 3
Adjustment range : ±
00.02
rpm
Factory setting
: 0
Used to define preset reference Pr3.
: Preset reference 4
Adjustment range : ±
00.02
rpm
Factory setting
: 0
Used to define preset reference Pr4.
: Catch a spinnin
g
motor
Adjustment range : DISABLED (0), 2 DIRECTIONS (1),
CLOCKWISE (2), C/CLOCKWISE (3),
2 Dir Reman. (4)
Factory setting
: DISABLED (0)
If this parameter is enabled (
00.50
z
DISABLED (0)), when
there is a run command or after a mains supply break, the
drive executes a procedure to calculate the motor frequency
and direction of rotation. It will automatically recalibrate the
output frequency to the measured value and reaccelerate the
motor up to the reference frequency.
DISABLED (0): Disable flyin
g
restart on a motor which is
rotatin
g
.
2 DIRECTIONS (1):
Enable flying restart on a motor which is
rotating clockwise or counter-clockwise
CLOCKWISE (2):
Enable flying restart on a motor which is
rotating clockwise.
C/CLOCKWISE (3):
Enable flying restart on a motor which is
rotating counter-clockwise.
2 Dir Reman. (4):
Enable flying restart on a motor which is
rotating clockwise or counter-clockwise by measuring the
remanent voltage (only if the measure remanent voltage
option is available).
Not available in the current version.
• If the load is stationary at the time of the run
command or when the mains supply returns, this
operation may cause the machine to rotate in both
directions before the motor accelerates.
• Before enablin
g
this function, check that there is
no dan
g
er to e
q
uipment and personnel.