5.17.2 - Explanation of parameters in menu 16
: Timer 1 output
Adjustment range : Disabled (0) or Enabled (1)
This parameter indicates the state of the output of timer 1.
: Timer 1 source
Adjustment range :
00.00
to
21.51
Factory setting
:
00.00
This parameter is used to select the input source for timer
relay 1.
Only "bit" type parameters can be assigned to these inputs. If
an unsuitable parameter is addressed, the input will be frozen
at 0.
: Timer 1 mode select
Adjustment range : ON timer (0) or OFF timer (1)
Factory setting
: ON timer (0)
ON timer (0): The relay is used for on-delay timin
g
. The
output chan
g
in
g
to Enabled (1) is delayed in relation to
the input chan
g
in
g
to 1.
OFF timer (1):
The relay is used for off-delay timing. The
output changing to Disabled (0) is delayed in relation to the
input changing to 0.
Note:
Powering-up of the drive is not taken into account as a
transition of the input; the timer is therefore not activated.
: Timer 1 unit
Adjustment range : Second (0), Minute (1), Hour (2)
Factory setting
: Second (0)
Second (0): The unit of time for the timer relay is the
second.
Minute (1):
The unit of time for the timer relay is the minute.
Hour (2):
The unit of time for the timer relay is the hour.
: Timer 1 value
Adjustment range : 0 to 60.0
Factory setting
: 0
This parameter is used to set the delay period for timer 1. The
unit depends on the setting of
16.04
.
to
: Not used
: Timer 1 output destination
Adjustment range :
00.00
to
21.51
Factory setting
:
00.00
This parameter is used to select the destination of the output
for timer 1.
Only "bit" type parameters can be assigned to these outputs.
If an unsuitable parameter is addressed, the output will be
frozen at 0.
: Not used
: Timer 2 output
Adjustment range : Disabled (0) or Enabled (1)
This parameter indicates the state of the output of timer 2.
: Timer 2 source
Adjustment range :
00.00
to
21.51
Factory setting
:
00.00
This parameter is used to select the input source for timer
relay 2.
Only "bit" type parameters can be assigned to these inputs. If
an unsuitable parameter is addressed, the input will be frozen
at 0.
: Timer 2 mode select
Adjustment range : ON timer (0) or OFF timer (1)
Factory setting
: ON timer (0)
ON timer (0): The relay is used for on-delay timin
g
. The
output chan
g
in
g
to Enabled (1) is delayed in relation to
the input chan
g
in
g
to 1.
OFF timer (1):
The relay is used for off-delay timing. The
output changing to Disabled (0) is delayed in relation to the
input changing to 0.
Note:
Powering-up of the drive is not taken into account as a
transition of the input; the timer is therefore not activated.
: Timer 2 unit
Adjustment range : Second (0), Minute (1), Hour (2)
Factory setting
: Second (0)
Second (0): The unit of time for the timer relay is the
second.
Minute (1):
The unit of time for the timer relay is the minute.
Hour (2):
The unit of time for the timer relay is the hour.
: Timer 2 value
Adjustment range : 0 to 60.0
Factory setting
: 0
This parameter is used to set the delay period for timer 2. The
unit depends on the setting of
16.14
.
to
: Not used
: Timer 2 output destination
Adjustment range :
00.00
to
21.51
Factory setting
:
00.00
This parameter is used to select the destination of the output
for timer 2.
Only "bit" type parameters can be assigned to these outputs.
If an unsuitable parameter is addressed, the output will be
frozen at 0.
: Not used
: Timer 3 output
Adjustment range : Disabled (0) or Enabled (1)
This parameter indicates the state of the output of timer 3.
: Timer 3 source
Adjustment range :
00.00
to
21.51
Factory setting
:
00.00
This parameter is used to select the input source for timer
relay 3.
Only "bit" type parameters can be assigned to these inputs. If
an unsuitable parameter is addressed, the input will be frozen
at 0.
16.01
16.02
16.03
16.04
16.05
16.06
16.08
16.09
16.10
16.11
16.12
16.13
16.14
16.15
16.16
16.18
16.19
16.20
16.21
16.22