13
COMMISSIONING MANUAL
POWERDRIVE MD
Variable speed drive
PARAMETER SETTING INTERFACE
LEROY-SOMER
3871 en - 2011.05 / h
2.2.3.4 - Keypad control set up
"KEYPAD CONTROL SET UP"
is used to configure the controls possible from the Human-Machine Interface (Run Forward/Run
Backward, Stop, Speed reference). Access is protected by a code.
For "Keypad control set up" it is necessary to disconnect terminals SDI1 and SDI2.
NO
YES
NO
Stop/Run Forward
Stop/Run Fwd/
and Run Backwd
No speed adjustment via the HMI.
3 buttons for adjusting the speed reference are displayed.
No Run Fwd/Run Backwd/Stop command via the HMI.
Two buttons, Forward and Stop, are displayed.
Three buttons, Forward, Stop and Backward, are displayed.
Setup possible
Effects on the "KEYPAD CONTROL" page
Touch button for increasing
the speed reference
On pressing the
"Speed reference"
button, the number pad is displayed for direct
entry of the desired speed reference.
The + and - buttons will then allow the value to be adjusted more easily.
Touch button for
decreasing the
speed reference
Touch buttons for giving
the following commands:
- Forward,
- Backward,
- Stop.
Drive status
Display showing
the motor status
Press , then type in the access code
"149"
and confirm using the
"ENT"
button.
Press
"SET"
to confirm the new settings.