Commissioning
Course program
Application examples
5
97
SW-HB 13.0002-EN EN 3.0
Linear linkage of positions with digital output setting
Positions 1 – 2 – 3 – 18 are to be approached. The drive is to stop for 1 second at every
position. Then, the course program shall stop.
When position 3 is reached, the digital output DOUT1 shall be set to HIGH for one second.
Pos 1
Pos 2
Pos 3
Pos 18
Start
Stop
931E_119
Fig. 16
Linear linkage of positions with digital output setting
Implementation:
931e_262
Implementation:
ƒ
Positions 1, 2, 3 and 18 are parameterised with a start delay of 1 second.
ƒ
The setting ”Target reached” for DOUT1 must stand in line 3 because the setting
”On” or ”Off” will be accepted immediately and the signal will thus not be active for
one second. When position 18 is approached, DOUT1 will be deleted.
efesotomasyon.com - Lenze