Appendix
Parameterisation of outside motors
User-defined display unit settings
10
153
SW-HB 13.0002-EN EN 3.0
10.1.12
User-defined display unit settings
Go to the
Display mode
field and activate
User-defined
to adapt the display units to your
application.
931e_306
aáëéä~ó ìåáíë
Note!
All user-defined units are displayed with [...].
Use the
Translatory application, Feed constant
field to enter the scaling in user-defined
units per revolution.
Example:
You have a drive with 1.76 inch per revolution, without gearbox and want to enter the
position in inch. Enter 1.76 under Feed constant.
Furthermore, you can use the
Time base speed
and
Time base acceleration
input fields.
Use the
Time base speed
field to define your own speed units.
Example: (rotary operation)
You have a drive with 20 mm per revolution, without gearbox and want to enter the speed
in mm/minute. Enter 20 under Feed constant and 60 under Time base speed
(60 seconds = 1 minute).
Use the
Time base acceleration
field to define your own acceleration units.
Example:
You have a drive with 20 mm per revolution, without gearbox and want to enter the
acceleration in (mm/minute)/sec. Enter 20 under Feed constant and 60 under Time base
speed (1 minute x 1 sec = 60 x 1 sec
2
= 60 sec
2
).
efesotomasyon.com - Lenze