Digital outputs and analog inputs and outputs
Digital outputs DOUT1, DOUT2
7
108
SW-HB 13.0002-EN EN 3.0
Settings
Select the menu
Parameters
I/Os
Digital outputs
to set the parameters of the digital
outputs DOUT1 and DOUT2.
931e_318
DOUT1 and DOUT2 can each be independently assigned with one of the following signals:
ƒ
OFF, i.e. output inactive, LOW level via integrated pull-down resistor
ƒ
ON, i.e. output active, 24 V HIGH level via integrated high-side switch
ƒ
Power stage active, i.e. power stage switched on
ƒ
I
@
T message motor / servo
ƒ
Group warning
ƒ
Group error message
ƒ
Following error
ƒ
Remaining path message
ƒ
Target reached
ƒ
Homing completed
ƒ
Comparison speed reached
ƒ
Course program
With some selections, there is a button with three points behind the selection box. If you
click this button, a window opens in which you can enter additional settings.
Setting the messages for the digital outputs
When used together with a control, it may be useful in many applications that the servo
positioning controller generates a message, if the selected operating conditions are not
complied with or not reached. Select the menu item
Parameters
Messages
to open the
window for setting the messages. Here, you can select the tolerance margins for the
messages ”Comparison speed reached”, ”Target reached” and ”Following error”.