Digital outputs and analog inputs and outputs
Holding brake DOUT3
7
112
SW-HB 13.0002-EN EN 3.0
t
F
t
A
t
t
t
t
t
931E_117
Fig. 27
Time behaviour of the holding brake
Controller enable
Power stage active
Holding brake released
Speed setpoint
Actual speed
t
F
Run delay
t
A
Stop delay
Note!
After controller enable, speed setpoints or positioning start commands will
only become effective after the run delay.
With torque control, the torque setpoints will be activated/deactivated at the time of
internal controller enable.
efesotomasyon.com - Lenze