Creating a RAID volume
Attention:
All the existing data stored on the selected drives will be erased while the RAID volume is being
created.
To create a RAID volume, do the following:
1. Start the Setup Utility program. See “Starting the Setup Utility program” on page 67.
2. Select
Advanced
➙
AVAGO MegaRAID Configuration Utility
and press Enter.
3. Select
Main Menu
and press Enter.
4. Select
Configuration Management
and press Enter.
5. Select
Create Virtual Drive
and press Enter.
6. Select and configure the options one by one.
a.
Select RAID Level
: You can set the RAID level to one of the following:
•
RAID0
•
RAID1
•
RAID5
•
RAID6
•
RAID00
•
RAID10
Note:
Some of the RAID levels might not be displayed because the number of installed SATA
storage drives and the model of the AVAGO MegaRAID adapter vary.
b.
Select Drives From
: Select
Unconfigured capacity
or
Free capacity
depending on your needs and
press Enter.
c.
Select Drives
: Select a storage drive and press Enter. After selecting all storage drives for creating
the RAID volume, select
Apply Changes
and press Enter. When promoted, select
Confirm
and
press Enter. Then, select
Yes
and press Enter to save the storage drive selection. Finally, select
OK
and press Enter.
d.
Virtual Drive Name
: You can type a preferred name for the volume name.
e.
Strip Size
(if applicable): Select a strip size and press Enter.
7. Select
Save Configuration
and press Enter. When promoted, select
Confirm
and press Enter. Then,
select
Yes
and press Enter to confirm the creation of the RAID volume.
8. To save settings and exit the Setup Utility program, press F10 or Fn+F10 (depending on the keyboard
settings), select
Yes
in the window displayed, and press Enter.
Viewing the information about a RAID volume
To view the information about a RAID volume, do the following:
1. Start the Setup Utility program. See “Starting the Setup Utility program” on page 67.
2. Select
Advanced
➙
AVAGO MegaRAID Configuration Utility
and press Enter.
3. Select
Main Menu
and press Enter.
4. Select
Virtual Drive Management
and press Enter.
5. Select a RAID volume and press Enter to view the detailed information.
Deleting a RAID volume
Attention:
All the existing data stored on the selected drives will be erased after you delete RAID volumes.
77
Summary of Contents for ThinkStation P920
Page 1: ...P920 Hardware Maintenance Manual Machine Types 30BD 30BV and 30BC ...
Page 6: ...iv P920 Hardware Maintenance Manual ...
Page 8: ...vi P920 Hardware Maintenance Manual ...
Page 16: ...8 P920 Hardware Maintenance Manual ...
Page 20: ...12 P920 Hardware Maintenance Manual ...
Page 21: ...1 2 Chapter 1 Read this first Important safety information 13 ...
Page 22: ...14 P920 Hardware Maintenance Manual ...
Page 28: ...20 P920 Hardware Maintenance Manual ...
Page 32: ...24 P920 Hardware Maintenance Manual ...
Page 36: ...28 P920 Hardware Maintenance Manual ...
Page 43: ...Figure 4 Major FRUs and CRUs Chapter 2 Product overview 35 ...
Page 68: ...60 P920 Hardware Maintenance Manual ...
Page 74: ...66 P920 Hardware Maintenance Manual ...
Page 102: ...94 P920 Hardware Maintenance Manual ...
Page 220: ...212 P920 Hardware Maintenance Manual ...
Page 224: ...216 P920 Hardware Maintenance Manual ...
Page 226: ...218 P920 Hardware Maintenance Manual ...
Page 228: ...220 P920 Hardware Maintenance Manual ...
Page 236: ...228 P920 Hardware Maintenance Manual ...
Page 240: ...232 P920 Hardware Maintenance Manual ...
Page 242: ...234 P920 Hardware Maintenance Manual ...
Page 244: ...236 P920 Hardware Maintenance Manual ...
Page 245: ......
Page 246: ......