Configuring the controller
By running ServeRAID Manager in Startable CD mode, you can configure the
controller before you install the operating system. The information in this section
assumes that you are running ServeRAID Manager in Startable CD mode.
To run ServeRAID Manager in Startable CD mode, turn on the server; then, insert
the IBM
ServeRAID Support
CD into the CD or DVD drive. If ServeRAID Manager
detects an unconfigured controller and ready drives, the Configuration wizard starts.
In the Configuration wizard, you can select express configuration or custom
configuration. Express configuration automatically configures the controller by
grouping the first two physical drives in the ServeRAID Manager tree into an array
and creating a RAID level-1 logical drive. If you select custom configuration, you
can select the two physical drives that you want to group into an array and create a
hot-spare drive.
Using express configuration:
To use express configuration, complete the
following steps:
1. In the ServeRAID Manager tree, click the controller.
2. Click
Express configuration
.
3. Click
Next
.
4. In the “Configuration summary” window, review the information. To change the
configuration, click
Modify arrays
or
Modify logical drives
.
Note:
Some operating systems have size limitations for logical drives. Before
you save the configuration, make sure that the size of the logical drive is
appropriate for your operating system.
5. Click
Apply
; when you are asked whether you want to apply the new
configuration, click
Yes
. The configuration is saved in the controller and in the
physical drives.
6. Exit from ServeRAID Manager and remove the CD from the CD or DVD drive.
7. Restart the server.
Using custom configuration
:
To use custom configuration, complete the
following steps:
1. In the ServeRAID Manager tree, click the controller.
2. Click
Custom configuration
.
3. Click
Next
.
4. In the “Create arrays” window, from the list of ready drives, select the two
drives that you want to move into the array.
5. Click the (Add selected drives) icon to add the drives to the array.
6. If you want to configure a hot-spare drive, complete the following steps:
a. Click the
Spares
tab.
b. Select the physical drive that you want to designate as the hot-spare drive,
and click the icon to add the drive.
7. Click
Next
.
8. In the “Configuration summary” window, review the information. To change the
configuration, click
Back
.
9. Click
Apply
; when you are asked whether you want to apply the new
configuration, click
Yes
. The configuration is saved in the controller and in the
physical drives.
Chapter 2. Configuration information and instructions
21
Summary of Contents for ThinkServer TD100
Page 2: ......
Page 18: ...xvi ThinkServer TD100 and TD100x Hardware Maintenance Manual ...
Page 42: ...24 ThinkServer TD100 and TD100x Hardware Maintenance Manual ...
Page 238: ...220 ThinkServer TD100 and TD100x Hardware Maintenance Manual ...
Page 253: ......
Page 254: ...Part Number 46U0860 Printed in USA 1P P N 46U0860 ...