v
Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v
See Chapter 3, “Parts listing, TD100 Types 6398, 6399, 6419, 6429, 4203, and 4206,” on page 25 to
determine which components are customer replaceable units (CRU) and which components are field
replaceable units (FRU).
v
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Error code
Description
Action
I9990305
An operating system was not found.
1. Make sure that a bootable operating system is
installed. To determine whether an operating
system is one of the devices in the startup
sequence, run the Configuration/Setup Utility
program (see the
User’s Guide
on the IBM
System x3400 Documentation
CD).
2. Run the hard disk drive diagnostic tests.
3. Reseat the following components, depending on
the server model:
v
Hot-swap models:
a. Hard disk drive
b. Hard disk drive cable
c. Hard disk drive backplane
v
Simple-swap models:
a. Hard disk drive
b. Hard disk drive cable
4. Replace the following components one at a time,
depending on the server model, in the order
shown, restarting the server each time:
v
Hot-swap models:
a. Hard disk drive
b. Hard disk drive cable
c. Hard disk drive backplane
v
Simple-swap models:
a. Hard disk drive
b. Hard disk drive cable
5. (Trained service technician only) Replace the
system board.
I9990650
AC power has been restored.
1. Reseat the power cords.
2. Check for interruption of the external power.
3. Replace the power cords.
4. For hot-swap models, replace the power supply
backplane.
Chapter 5. Diagnostics
169
Summary of Contents for ThinkServer TD100
Page 2: ......
Page 18: ...xvi ThinkServer TD100 and TD100x Hardware Maintenance Manual ...
Page 42: ...24 ThinkServer TD100 and TD100x Hardware Maintenance Manual ...
Page 238: ...220 ThinkServer TD100 and TD100x Hardware Maintenance Manual ...
Page 253: ......
Page 254: ...Part Number 46U0860 Printed in USA 1P P N 46U0860 ...