v
Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v
See Chapter 3, “Parts listing, TD100 Types 6398, 6399, 6419, 6429, 4203, and 4206,” on page 25 to
determine which components are customer replaceable units (CRU) and which components are field
replaceable units (FRU).
v
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
System-error log message
Action
OS Watchdog response enabled by
x
Information only.
PFA Alert, see preceding error in system error
log
Information only. See the preceding entry in the system-error log.
Possible ASM reset occurred -- reason unknown Information only.
Power off
Information only.
Power on
Information only.
PPP[
xxx
] PPP-Cfg, Local-
IP@=
aaa.aaa.aaa.aaa
, Remote-
IP@=
bbb.bbb.bbb.bbb
NetMsk=
ccc.ccc.ccc.ccc
,
Auth=
ddd
Information only.
PPP_1:Client Connected at
xxx
bps
Information only.
PPP_1:User requested to abort PPP interface
Information only.
Received alert from system
x
; type:
y
, sender’s
ID:
z
Information only.
Remote access attempt failed
Information only.
Remote access attempt failed. Invalid userid or
password received. Userid is ’
x
’ from WEB
browser at IP@=
yyy.yyy.yyy.yyy
Information only.
Remote access attempt failed. Invalid userid or
password received. Userid is ’
x
’ from CMD
mode client at IP@=
yyy.yyy.yyy.yyy
Information only.
Remote access attempt failed. Invalid userid or
password received. Userid is ’
x
’ from TELNET
client at IP@=
yyy.yyy.yyy.yyy
Information only.
Remote Login Successful. Login ID:
Information only.
Remote Login Successful. Login ID:’
x
’ from
CMD mode client at IP@=
yyy.yyy.yyy.yyy
Information only.
Retried alert accepted from system
x
; type:
y
,
sender’s ID:
z
Information only.
Retry count exceeded. Incorrect password
entered too many times for userid
w
,
x
,
y
,
z
Information only.
RS485 broadcast from
x
ignored; more than
y
devices present on the RS485 network
Information only.
RS485 connection to system
x
has ended
Information only.
RS485 network overload has cleared;
x
or fewer
devices are present on the RS485 network
Information only.
RSA
x
Became the ISMP Gateway
Information only.
Running the backup ASM main application
Information only.
Secondary Device Event[00
x
UNKNOWN-
y
]
Information only.
Sending alert to remote system
x
; type:
y
, ID:
z
Information only.
208
ThinkServer TD100 and TD100x: Hardware Maintenance Manual
Summary of Contents for ThinkServer TD100
Page 2: ......
Page 18: ...xvi ThinkServer TD100 and TD100x Hardware Maintenance Manual ...
Page 42: ...24 ThinkServer TD100 and TD100x Hardware Maintenance Manual ...
Page 238: ...220 ThinkServer TD100 and TD100x Hardware Maintenance Manual ...
Page 253: ......
Page 254: ...Part Number 46U0860 Printed in USA 1P P N 46U0860 ...