Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v
See Chapter 3, “Parts listing, TD100 Types 6398, 6399, 6419, 6429, 4203, and 4206,” on page 25 to
determine which components are customer replaceable units (CRU) and which components are field
replaceable units (FRU).
v
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Error code
Description
Action
5962
IDE CD or DVD drive configuration error.
1. Run the Configuration/Setup Utility program and
load the default settings (see “Using the
Configuration/Setup Utility program” on page 16).
2. Reseat the following components:
v
CD or DVD drive cable
v
CD or DVD drive
3. Replace the components listed in step 2 one at a
time, in the order shown, restarting the server
each time.
4. (Trained service technician only) Replace the
system board
8603
Pointing-device error.
1. Reseat the pointing device.
2. Replace the following components one at a time,
in the order shown, restarting the server each
time:
a. Pointing device
b. (Trained service technician only) System
board
00012000
Processor machine check error.
1. (Trained service technician only) Reseat the
microprocessor.
2. Replace the following components one at a time,
in the order shown, restarting the server each
time:
a. (Trained service technician only)
Microprocessor
b. (Trained service technician only) System
board
0001295
ECC circuit check.
1. Reseat DIMMs
2. Replace the DIMMs, one at a time, restarting the
server each time.
00019501
Processor 1 is not functioning; check VRM
and processor LEDs.
1. (Trained service technician only) Reseat
microprocessor 1. If two microprocessors are
installed, remove microprocessor 1 and replace it
with microprocessor 2 to determine if the
microprocessor or the system board failed.
2. Replace the following components one at a time,
in the order shown, restarting the server each
time:
a. (Trained service technician only)
Microprocessor 1
b. (Trained service technician only) System
board
Chapter 5. Diagnostics
165
Summary of Contents for ThinkServer TD100
Page 2: ......
Page 18: ...xvi ThinkServer TD100 and TD100x Hardware Maintenance Manual ...
Page 42: ...24 ThinkServer TD100 and TD100x Hardware Maintenance Manual ...
Page 238: ...220 ThinkServer TD100 and TD100x Hardware Maintenance Manual ...
Page 253: ......
Page 254: ...Part Number 46U0860 Printed in USA 1P P N 46U0860 ...