v
Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v
See Chapter 3, “Parts listing, TD100 Types 6398, 6399, 6419, 6429, 4203, and 4206,” on page 25 to
determine which components are customer replaceable units (CRU) and which components are field
replaceable units (FRU).
v
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Error code
Description
Action
166-400-100
DMC Self Test Result failed tests: xxx where
xxx=flash, ROM, or RAM.
1. Disconnect all server and option power cords
from the server, wait 30 seconds, reconnect the
power cords, and retry.
2. Update the BIOS code, BMC, service processor,
and diagnostics firmware (see “Updating the
firmware” on page 15).
180-197-000
SCSI ASPI driver not installed.
1. Remove the RAID adapter, if one is installed, and
run the test again.
2. Reseat the SAS/SATA hard disk drive backplane
cables.
3. Replace the following components one at a time,
in the order shown, restarting the server each
time:
a. SAS/SATA hard disk drive backplane
b. (Trained service technician only) System
board
180-361-003
Failed fan LED test.
1. Reseat the fan.
2. Replace the following components one at a time,
in the order shown, restarting the server each
time:
a. Fan
b. (Trained service technician only) System
board
180-xxx-000
Diagnostics LED failure.
Run the diagnostic LED test for the failing LED.
180-xxx-001
Failed front LED panel test.
1. Reseat the control-panel assembly cable.
2. Replace the following components one at a time,
in the order shown, restarting the server each
time:
a. Control-panel assembly cable
b. (Trained service technician only) System
board
180-xx-002
Failed diagnostics LED panel test.
1. Reseat the control-panel assembly cable.
2. Replace the following components one at a time,
in the order shown, restarting the server each
time:
a. Control-panel assembly cable
b. (Trained service technician only) System
board
198
ThinkServer TD100 and TD100x: Hardware Maintenance Manual
Summary of Contents for ThinkServer TD100
Page 2: ......
Page 18: ...xvi ThinkServer TD100 and TD100x Hardware Maintenance Manual ...
Page 42: ...24 ThinkServer TD100 and TD100x Hardware Maintenance Manual ...
Page 238: ...220 ThinkServer TD100 and TD100x Hardware Maintenance Manual ...
Page 253: ......
Page 254: ...Part Number 46U0860 Printed in USA 1P P N 46U0860 ...