v
Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v
See Chapter 3, “Parts listing, TD100 Types 6398, 6399, 6419, 6429, 4203, and 4206,” on page 25 to
determine which components are customer replaceable units (CRU) and which components are field
replaceable units (FRU).
v
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
System-error log message
Action
Serial tamper delay triggered. Possible serial
port break-in attempt
Information only.
System board is over recommended
temperature
1. Make sure that the fans have good airflow and are not
obstructed.
2. (Trained service technician only) Replace the system board.
System board is under recommended
temperature
1. Make sure that the fans have good airflow and are not
obstructed.
2. (Trained service technician only) Replace the system board.
System Complex Powered Down
Information only.
System error log full
Clear the current logs.
System is over recommended voltage for +3.3V
1. Reseat the following components:
a. Hot-swap power supplies (if any are installed)
b. (Trained service technician only) Power-supply cables on
the system board
2. (Trained service technician only) Replace the system board.
System is over recommended voltage for 1.5V
CPU
1. Reseat the following components:
a. Hot-swap power supplies (if any are installed)
b. (Trained service technician only) Power-supply cables on
the system board
2. (Trained service technician only) Replace the system board.
System is over recommended voltage on the
VRM
(Trained service technician only) Reseat the microprocessor.
System is under recommended voltage for
+3.3V
1. Reseat the following components:
a. Hot-swap power supplies (if any are installed)
b. (Trained service technician only) Power-supply cables on
the system board
2. (Trained service technician only) Replace the system board.
System is under recommended voltage for 1.5V
CPU
1. Reseat the following components:
a. Hot-swap power supplies (if any are installed)
b. (Trained service technician only) Power-supply cables on
the system board
2. (Trained service technician only) Replace the system board.
System is under recommended voltage on the
VRM
(Trained service technician only) Reseat the microprocessor.
System log 75% full
Clear the current logs.
System log cleared
Information only.
System Memory Error
1. Reseat the DIMMs.
2. Replace the DIMMs.
Chapter 5. Diagnostics
209
Summary of Contents for ThinkServer TD100
Page 2: ......
Page 18: ...xvi ThinkServer TD100 and TD100x Hardware Maintenance Manual ...
Page 42: ...24 ThinkServer TD100 and TD100x Hardware Maintenance Manual ...
Page 238: ...220 ThinkServer TD100 and TD100x Hardware Maintenance Manual ...
Page 253: ......
Page 254: ...Part Number 46U0860 Printed in USA 1P P N 46U0860 ...