v
Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v
See Chapter 3, “Parts listing, TD100 Types 6398, 6399, 6419, 6429, 4203, and 4206,” on page 25 to
determine which components are customer replaceable units (CRU) and which components are field
replaceable units (FRU).
v
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Error code
Description
Action
1962
A hard disk drive does not contain a valid
boot sector.
1. Make sure that a bootable operating system is
installed.
2. Run the hard disk drive diagnostic tests.
3. Reseat the following components, depending on
the server model:
v
Hot-swap and non-hot-swap models:
a. Hard disk drive
b. Hard disk drive cable
c. Optional adapter cable
d. SAS/SATA backplane
v
Simple-swap models:
a. Hard disk drive
b. Hard disk drive cable
c. Optional adapter cable
d. SATA backplate
4. Replace the following components one at a time,
depending on the server model, in the order
shown, restarting the server each time:
v
Hot-swap and non-hot-swap models:
a. Hard disk drive
b. Hard disk drive cable
c. Optional adapter cable
d. SAS/SATA backplane
v
Simple-swap models:
a. Hard disk drive
b. Hard disk drive cable
c. Optional adapter cable
d. SATA backplate
5. (Trained service technician only) Replace the
system board.
2462
Video configuration error occurred.
1. Reseat the video adapter, if one is installed.
2. (Trained service technician only) Replace the
system board.
164
ThinkServer TD100 and TD100x: Hardware Maintenance Manual
Summary of Contents for ThinkServer TD100
Page 2: ......
Page 18: ...xvi ThinkServer TD100 and TD100x Hardware Maintenance Manual ...
Page 42: ...24 ThinkServer TD100 and TD100x Hardware Maintenance Manual ...
Page 238: ...220 ThinkServer TD100 and TD100x Hardware Maintenance Manual ...
Page 253: ......
Page 254: ...Part Number 46U0860 Printed in USA 1P P N 46U0860 ...