4. From the list of ready drives, select the two drives that you want to group into
the array.
5. When you are prompted to select the RAID level, select
RAID 0
or
RAID-1
.
6. (Optional) Type an identifier for the array.
7. When you are prompted for the array build method, select
Quick Init
.
8. Follow the instructions on the screen to complete the configuration, and select
Done
to exit.
9. Restart the server.
Viewing the array configuration:
To view information about the RAID array,
complete the following steps:
1. Start the Adaptec RAID Configuration Utility program.
2. Start the Array Configuration Utility.
3. From the Array Configuration Utility window, select
Manage Arrays
.
4. Select an array and press Enter.
5. Press Esc to exit from the program.
For additional information about using the Adaptec RAID Configuration Utility
program to create, configure, and manage arrays, see the documentation on the
IBM
ServeRAID-8e (Adaptec HostRAID) Support
CD.
Using RAID Manager
Important:
RAID options and HostRAID are not supported on the SCO 6.0 and
UnixWare 7.14 operating systems.
Use ServeRAID Manager, which is on the IBM
ServeRAID Manager Application
CD,
to perform the following tasks:
v
Configure a redundant array of independent disks (RAID) array
v
Restore a SAS or SATA hard disk drive to the factory-default settings, erasing all
data from the disk
v
View the RAID configuration and associated devices
v
Monitor the operation of the RAID controllers
To perform some tasks, you can run ServeRAID Manager as an installed program.
However, to configure the integrated RAID controller or the installed ServeRAID
controller and perform an initial RAID configuration on the server, you must run
ServeRAID Manager in Startable CD mode, as described in the instructions in this
section. If you install a different type of RAID adapter in the server, use the method
that is described in the instructions that come with the adapter to view or change
settings for attached devices.
See the ServeRAID documentation on the IBM
ServeRAID Support
CD for
additional information about RAID technology and instructions for using ServeRAID
Manager to configure the RAID controller. Additional information about ServeRAID
Manager is also available from the
Help
menu. For information about a specific
object in the ServeRAID Manager tree, select the object and click
Actions
→
Hints
and tips.
20
ThinkServer TD100 and TD100x: Hardware Maintenance Manual
Summary of Contents for ThinkServer TD100
Page 2: ......
Page 18: ...xvi ThinkServer TD100 and TD100x Hardware Maintenance Manual ...
Page 42: ...24 ThinkServer TD100 and TD100x Hardware Maintenance Manual ...
Page 238: ...220 ThinkServer TD100 and TD100x Hardware Maintenance Manual ...
Page 253: ......
Page 254: ...Part Number 46U0860 Printed in USA 1P P N 46U0860 ...