v
Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v
See Chapter 3, “Parts listing, TD100 Types 6398, 6399, 6419, 6429, 4203, and 4206,” on page 25 to
determine which components are customer replaceable units (CRU) and which components are field
replaceable units (FRU).
v
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Error code
Description
Action
030-267-001
Central Management Seq error.
1. Update the microcode for the Serial Attached
SCSI (SAS)/SATA controller (see “Updating the
firmware” on page 15).
2. Update the BIOS code (see “Updating the
firmware” on page 15).
3. (Trained service technician only) Replace the
system board.
035-002-0nn
ServeRAID interface timeout.
1. Make sure that the ServeRAID controller is
configured correctly. Obtain the basic and
extended configuration status bytes and see the
ServeRAID documentation for more information.
2. Reseat the following components:
a. SAS/SATA hard disk drive backplane cable
b. ServeRAID controller
3. Replace the components listed in step 2 one at a
time, in the order shown, restarting the server
each time.
035-230-001
Battery Low.
Replace the battery module on the RAID controller.
035-231-001
Abnormal Battery Temperature.
Replace the battery module on the RAID controller.
035-285-001
Adapter Communication Error.
1. Update the RAID controller firmware (see
“Updating the firmware” on page 15).
2. Reseat the RAID controller.
3. Replace the RAID controller.
035-286-001
Adapter CPU Test Error.
1. Update the RAID controller firmware (see
“Updating the firmware” on page 15).
2. Reseat the RAID controller.
3. Replace the RAID controller.
035-287-001
Adapter Local RAM Test Error.
1. Update the RAID controller firmware (see
“Updating the firmware” on page 15).
2. Reseat the RAID controller.
3. Replace the RAID controller.
035-288-001
Adapter NVSRAM Test Error.
1. Update the RAID controller firmware (see
“Updating the firmware” on page 15).
2. Reseat the RAID controller.
3. Replace the RAID controller.
035-289-001
Adapter Cache Test Error.
1. Update the RAID controller firmware (see
“Updating the firmware” on page 15).
2. Reseat the RAID controller.
3. Replace the RAID controller.
Chapter 5. Diagnostics
193
Summary of Contents for ThinkServer TD100
Page 2: ......
Page 18: ...xvi ThinkServer TD100 and TD100x Hardware Maintenance Manual ...
Page 42: ...24 ThinkServer TD100 and TD100x Hardware Maintenance Manual ...
Page 238: ...220 ThinkServer TD100 and TD100x Hardware Maintenance Manual ...
Page 253: ......
Page 254: ...Part Number 46U0860 Printed in USA 1P P N 46U0860 ...