v
Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v
See Chapter 3, “Parts listing, TD100 Types 6398, 6399, 6419, 6429, 4203, and 4206,” on page 25 to
determine which components are customer replaceable units (CRU) and which components are field
replaceable units (FRU).
v
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
System-error log message
Action
System shutoff due to VRM over voltage
1. (Trained service technician only) Reseat the microprocessor.
2. Replace the following components one at a time, in the order
shown, restarting the server each time:
a. (Trained service technician only) Microprocessor
b. (Trained service technician only) System board
System shutoff due to VRM under voltage
1. (Trained service technician only) Reseat the microprocessor.
2. Replace the following components one at a time, in the order
shown, restarting the server each time:
a. (Trained service technician only) Microprocessor
b. (Trained service technician only) System board
System under recommended voltage for +12v
1. Reseat the following components:
a. Hot-swap power supplies (if any are installed)
b. (Trained service technician only) Power-supply cables on
the system board
2. (Trained service technician only) Replace the system board.
System under recommended voltage on +2.5v
1. Reseat the following components:
a. Hot-swap power supplies (if any are installed)
b. (Trained service technician only) Power-supply cables on
the system board
2. (Trained service technician only) Replace the system board.
System under recommended voltage on
cont5v
1. Reseat the following components:
a. Hot-swap power supplies (if any are installed)
b. (Trained service technician only) Power-supply cables on
the system board
2. (Trained service technician only) Replace the system board.
System
x
started a RS485 connection with us
Information only.
We started a RS485 connection with remote
system
x
Information only.
We will retry sending alert ID
x
; when accepted
by a remote system, it will have a different ID
Information only.
Windows blue screen has been captured
Information only.
212
ThinkServer TD100 and TD100x: Hardware Maintenance Manual
Summary of Contents for ThinkServer TD100
Page 2: ......
Page 18: ...xvi ThinkServer TD100 and TD100x Hardware Maintenance Manual ...
Page 42: ...24 ThinkServer TD100 and TD100x Hardware Maintenance Manual ...
Page 238: ...220 ThinkServer TD100 and TD100x Hardware Maintenance Manual ...
Page 253: ......
Page 254: ...Part Number 46U0860 Printed in USA 1P P N 46U0860 ...