Step 6. Verify basic switch operation by checking the system LEDs. When operating normally, the PSU1/
PSU2, Diag, and Fan LEDs should all be green.
Step 7. Connect the network cables.
a. For the RJ-45 Management port, connect 100-ohm Category 5, 5e or better twisted-pair cable.
b. Connect DAC cables to the SFP+/QSFP+ slots. Or first install SFP+/QSFP+ transceivers and
then connect fiber optic cabling to the transceiver ports.
The following transceivers are supported:
• 40G QSFP+ SR4 Transceiver 90Y3505
• 10G BASE-T (RJ45) SFP Transceiver SBB7A02090
• 10G SFP+ SR Transceiver 46C3446
Note:
As connections are made, check the port status LEDs to be sure the links are valid.
.