Install the compute enclosure
Procedures for installing ThinkAgile CP compute enclosure in a rack.
CAUTION:
Ensure that at least two people lift and install the enclosure together.
Figure 21. Front latches on slide rails
To install the ThinkAgile CP compute enclosure on the slide rails, do the following:
Step 1. Pull the slide rails forward until the rails click into place.
Step 2. Push up the front latches.
Step 3. Pull the slide rails all the way out.
Attention:
You can only install the compute block enclosure successfully when the slide rails are
fully extended.
Step 4. Remove all compute nodes and the shuttle from the enclosure.
Step 5. Carefully lift the enclosure.
Step 6. Tilt and lower the enclosure; then, push the slide rails toward the enclosure and make sure the
farthest nailheads on each side go into the slots on the slide rails.
.
35
Summary of Contents for ThinkAgile CP 4000 Series
Page 1: ...Lenovo ThinkAgile CP Hardware Installation Guide Models CP4000 CP6000 ...
Page 4: ...ii Lenovo ThinkAgile CP Hardware Installation Guide ...
Page 6: ...iv Lenovo ThinkAgile CP Hardware Installation Guide ...
Page 8: ...vi Lenovo ThinkAgile CP Hardware Installation Guide ...
Page 26: ...18 Lenovo ThinkAgile CP Hardware Installation Guide ...
Page 70: ...Figure 42 X Link option 1 topology 62 Lenovo ThinkAgile CP Hardware Installation Guide ...
Page 73: ...Figure 44 X Link topology option 2A Chapter 3 ThinkAgile CP Setup 65 ...
Page 78: ...70 Lenovo ThinkAgile CP Hardware Installation Guide ...
Page 80: ...72 Lenovo ThinkAgile CP Hardware Installation Guide ...
Page 82: ...74 Lenovo ThinkAgile CP Hardware Installation Guide ...
Page 83: ......
Page 84: ......