Complete the parts replacement. See “Complete the parts replacement” on page 113.
Air baffle replacement
Use this information to remove and install the air baffle.
The air baffle varies by the server hardware configuration. Select the appropriate air baffle for your server.
The replacement procedures for the air baffles are the same.
Remove the air baffle
Use this information to remove the air baffle.
About this task
S033
CAUTION:
Hazardous energy present. Voltages with hazardous energy might cause heating when shorted with
metal, which might result in spattered metal, burns, or both.
S017
CAUTION:
Hazardous moving fan blades nearby.
Attention:
• Read “Installation Guidelines” on page 25 to ensure that you work safely.
• Power off the server and disconnect all power cords for this task.
Procedure
Step 1. Prepare your server.
1. Remove the top cover. See “Remove the top cover” on page 30.
2. Disconnect the RAID super capacitor module cable, and remove the RAID super capacitor
module installed on the air baffle. See “Remove the RAID super capacitor module” on page 34.
3. Disconnect the M.2 drive cable, and remove the M.2 drive installed on the air baffle. See
“Remove the M.2 adapter and M.2 drive” on page 36.
.
Hardware replacement procedures
41
Summary of Contents for HR650X V2
Page 1: ...HR650X V2 User Guide Machine Types 7D4D ...
Page 8: ......
Page 14: ...6 HR650X V2 User Guide ...
Page 30: ...22 HR650X V2 User Guide ...
Page 122: ...114 HR650X V2 User Guide ...
Page 152: ...144 HR650X V2 User Guide ...
Page 176: ...168 HR650X V2 User Guide ...
Page 182: ...174 HR650X V2 User Guide ...
Page 186: ...178 HR650X V2 User Guide ...
Page 190: ...182 HR650X V2 User Guide ...
Page 191: ......
Page 192: ......