Procedure
Step 1. Touch the static-protective package that contains the RAID super capacitor module to any
unpainted surface on the outside of the server. Then, take the RAID super capacitor module out of
the package and place it on a static-protective surface.
Step 2. Install the super capacitor module.
Figure 13. RAID super capacitor module Installation on the air baffle
a. Open the retention clip on the holder.
b. Put the RAID super capacitor module into the air baffle.
c. Press it down to secure it into the holder.
After you finish
1. Connect the super capacitor module to an adapter with the extension cable that comes with the super
capacitor module.
2. Complete the parts replacement. See “Complete the parts replacement” on page 113.
M.2 adapter and M.2 drive replacement
Use this information to remove and install the M.2 adapter and M.2 drive.
This topic uses the M.2 module on the standard air baffle as an example for replacement illustration. The
replacement procedure is the same for the others.
• “Remove the M.2 adapter and M.2 drive” on page 36
• “Adjust the retainer on the M.2 adapter” on page 38
• “Install the M.2 adapter and M.2 drive” on page 38
Remove the M.2 adapter and M.2 drive
Use this information to remove the M.2 adapter and M.2 drive.
About this task
Attention:
• Read “Installation Guidelines” on page 25 to ensure that you work safely.
• Power off the server and disconnect all power cords for this task.
36
HR650X V2 User Guide
Summary of Contents for HR650X V2
Page 1: ...HR650X V2 User Guide Machine Types 7D4D ...
Page 8: ......
Page 14: ...6 HR650X V2 User Guide ...
Page 30: ...22 HR650X V2 User Guide ...
Page 122: ...114 HR650X V2 User Guide ...
Page 152: ...144 HR650X V2 User Guide ...
Page 176: ...168 HR650X V2 User Guide ...
Page 182: ...174 HR650X V2 User Guide ...
Page 186: ...178 HR650X V2 User Guide ...
Page 190: ...182 HR650X V2 User Guide ...
Page 191: ......
Page 192: ......