14ACX - 1.5 to 5 Ton Air Conditioner / Page 98
AHRI SYSTEM MATCHES - NORTH / SOUTH REGION - S018-S024-S030-S036-S042
NOTE - For the latest up-to-date system matches please visit the AHRI web site at
http://www.ahridirectory.org
Model
No.
Expansion
Device
Capacity SEER EER
Coil or
Air Handler
Furnace
AHRI
Reference
14ACXS036-230A
TXV
36,000
16.00
13.00
CH35-51C
SL280UH090XV60C
7626882
14ACXS036-230A
TXV
35,800
16.00
13.00
CH35-51C
SL280UH110V60C
7782768
14ACXS036-230A
TXV
35,800
16.00
13.00
CH35-51C
SL280UH110XV60C
7626885
14ACXS036-230A
TXV
35,400
16.00
13.00
CH35-51C
SLP98UH090XV36C
7782773
14ACXS036-230A
TXV
35,200
16.00
13.00
CH35-51C
SLP98UH090XV48C
7782774
14ACXS036-230A
TXV
35,800
16.00
13.00
CH35-51C
SLP98UH110XV60C
7626906
14ACXS036-230A
TXV
34,800
14.50
12.20
CH35-51C
7626877
14ACXS036-230A
TXV
33,600
14.50
12.20
CR33-30/36A
EL180DF045E36A
7626909
14ACXS036-230A
TXV
33,600
15.00
12.50
CR33-30/36A
SL280DF070V36A
7782776
14ACXS036-230A
TXV
33,600
15.50
12.50
CR33-30/36B
EL180DF070E36B
7782778
14ACXS036-230A
TXV
33,600
15.10
12.50
CR33-30/36B
EL180DF090E48B
7626916
14ACXS036-230A
TXV
33,400
14.50
12.00
CR33-30/36B
EL195DF045XE36B
7782779
14ACXS036-230A
TXV
33,600
15.10
12.50
CR33-30/36B
EL195DF070XE48B
7782780
14ACXS036-230A
TXV
33,400
14.50
12.00
CR33-30/36B
EL296DF045XE36B
7626919
14ACXS036-230A
TXV
33,600
15.00
12.20
CR33-30/36B
EL296DF045XV36B
7626924
14ACXS036-230A
TXV
33,600
15.10
12.50
CR33-30/36B
EL296DF070XE48B
7626922
14ACXS036-230A
TXV
33,600
14.50
12.20
CR33-30/36B
EL296DF070XV48B
7626927
14ACXS036-230A
TXV
33,800
15.10
12.50
CR33-30/36B
SL280DF090V48B
7626913
14ACXS036-230A
TXV
33,800
15.00
12.50
CR33-30/36B
SLP98DF070XV36B
7626930
14ACXS036-230A
TXV
33,400
14.25
11.50
CR33-30/36B
7782777
14ACXS036-230A
TXV
33,800
15.50
12.50
CR33-30/36C
EL180DF110E60C
7626938
14ACXS036-230A
TXV
33,600
15.10
12.50
CR33-30/36C
EL195DF090XE48C
7626940
14ACXS036-230A
TXV
33,600
15.10
12.50
CR33-30/36C
EL195DF110XE60C
7782781
14ACXS036-230A
TXV
33,600
15.10
12.50
CR33-30/36C
EL296DF090XE48C
7626943
14ACXS036-230A
TXV
34,000
15.10
12.50
CR33-30/36C
EL296DF090XV60C
7782783
14ACXS036-230A
TXV
33,600
15.10
12.50
CR33-30/36C
EL296DF110XE60C
7626946
14ACXS036-230A
TXV
34,000
15.10
12.50
CR33-30/36C
EL296DF110XV60C
7782784
14ACXS036-230A
TXV
34,000
15.50
12.50
CR33-30/36C
SL280DF110V60C
7626935
14ACXS036-230A
TXV
33,800
15.10
12.50
CR33-30/36C
SLP98DF090XV36C
7782782
14ACXS036-230A
TXV
33,800
15.10
12.50
CR33-30/36C
SLP98DF090XV48C
7626949
14ACXS036-230A
TXV
34,000
15.10
12.50
CR33-30/36C
SLP98DF090XV60C
7626952
14ACXS036-230A
TXV
34,000
15.10
12.50
CR33-30/36C
SLP98DF110XV60C
7626955
14ACXS036-230A
TXV
33,400
14.25
11.50
CR33-30/36C
7626932
14ACXS036-230A
TXV
34,200
15.00
12.50
CR33-48B
EL180DF070E36B
7783197
14ACXS036-230A
TXV
34,200
15.50
12.50
CR33-48B
EL180DF090E48B
7628444
14ACXS036-230A
TXV
34,000
15.10
12.50
CR33-48B
EL195DF045XE36B
7783198
14ACXS036-230A
TXV
34,000
15.50
12.50
CR33-48B
EL195DF070XE48B
7783199
14ACXS036-230A
TXV
34,000
15.50
12.50
CR33-48B
EL296DF045XE36B
7628447
14ACXS036-230A
TXV
34,200
15.10
12.50
CR33-48B
EL296DF045XV36B
7783200
14ACXS036-230A
TXV
34,000
15.50
12.50
CR33-48B
EL296DF070XE48B
7628450
14ACXS036-230A
TXV
34,200
15.10
12.50
CR33-48B
EL296DF070XV48B
7628453
14ACXS036-230A
TXV
34,600
15.50
12.50
CR33-48B
SL280DF090V48B
7628441
14ACXS036-230A
TXV
34,000
15.50
12.50
CR33-48B
SLP98DF070XV36B
7783201
14ACXS036-230A
TXV
33,800
14.25
12.00
CR33-48B
7783196
14ACXS036-230A
TXV
34,400
16.00
13.00
CR33-48C
EL180DF110E60C
7783203
14ACXS036-230A
TXV
34,200
15.50
12.50
CR33-48C
EL195DF090XE48C
7628462
14ACXS036-230A
TXV
34,200
15.50
12.50
CR33-48C
EL195DF110XE60C
7628465
14ACXS036-230A
TXV
34,200
15.50
12.50
CR33-48C
EL296DF090XE48C
7783204
14ACXS036-230A
TXV
34,600
15.50
12.50
CR33-48C
EL296DF090XV60C
7628471
NOTES:
TXV = Matched with Thermostatic Expansion Valve.
RFC = Matched with RFC metering device.
Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (
58M81
) for field installation. See furnace or air handler specifications to determine if relay is needed.
Also see Expansion Valve Kit Usage Table.