14ACX - 1.5 to 5 Ton Air Conditioner / Page 40
AHRI SYSTEM MATCHES - ALL REGIONS - 041-047-048-059-060
NOTE - For the latest up-to-date system matches please visit the AHRI web site at
http://www.ahridirectory.org
Model
No.
Expansion
Device
Capacity SEER EER
Coil or
Air Handler
Furnace
AHRI
Reference
14ACX-048-230
TXV
48,000
14.25
12.00
CX35-60D
EL195UH135XE60D
8267683
14ACX-048-230
TXV
48,000
14.25
12.00
CX35-60D
EL296UH135XE60D
8267685
14ACX-048-230
TXV
48,000
14.50
12.00
CX35-60D
EL296UH135XV60D
8267684
14ACX-048-230
TXV
48,000
15.00
12.50
CX35-60D
SL280UH135V60D
8267687
14ACX-048-230
TXV
48,000
14.50
12.00
CX35-60D
SLP98UH135XV60D
8267682
14ACX-048-230
TXV
48,000
14.00
11.70
CX35-60D
8267681
14ACX-059-230
TXV
56,500
15.00
12.20
C33-49
EL180UH090E60C
5736411
14ACX-059-230
TXV
56,500
15.00
12.20
C33-49
EL180UH110E60C
5738227
14ACX-059-230
TXV
56,500
14.70
12.20
C33-49
EL180UH110XE60C
5739166
14ACX-059-230
TXV
56,500
14.70
12.20
C33-49
EL195UH110XE60C
5053221
14ACX-059-230
TXV
56,500
14.70
12.20
C33-49
EL296UH110XE60C
5648039
14ACX-059-230
TXV
56,500
14.70
12.00
C33-49
EL296UH110XV60C
5431226
14ACX-059-230
TXV
56,500
15.00
12.20
C33-49
SL280UH090V60C
5053154
14ACX-059-230
TXV
56,500
14.70
12.20
C33-49
SL280UH110V60C
5053155
14ACX-059-230
TXV
56,500
14.70
12.20
C33-49
SL280UH110XV60C
5053156
14ACX-059-230
TXV
57,000
14.50
12.00
C33-49
SLP98UH090XV60C
5141539
14ACX-059-230
TXV
56,500
14.70
12.00
C33-49
SLP98UH110XV60C
5141540
14ACX-059-230
TXV
57,000
14.50
12.00
C33-49
5053098
14ACX-059-230
TXV
56,000
14.00
11.70
C33-50/60C
EL180UH110E60C
5738229
14ACX-059-230
TXV
55,500
14.50
12.00
C33-50/60C
SL280UH090V60C
5053161
14ACX-059-230
TXV
55,500
14.20
12.00
C33-50/60C
SL280UH110V60C
5053162
14ACX-059-230
TXV
55,500
14.20
12.00
C33-50/60C
SL280UH110XV60C
5053163
14ACX-059-230
TXV
55,500
14.20
11.70
C33-50/60C
SLP98UH110XV60C
5141542
14ACX-059-230
TXV
55,500
14.20
11.70
C33-50/60C
5053099
14ACX-059-230
TXV
57,000
15.00
12.20
C33-60D
EL180UH135E60D
5746022
14ACX-059-230
TXV
56,500
14.20
12.00
C33-60D
EL195UH135XE60D
5053226
14ACX-059-230
TXV
56,500
14.20
12.00
C33-60D
EL296UH135XE60D
5648044
14ACX-059-230
TXV
57,000
15.00
12.20
C33-60D
EL296UH135XV60D
5431227
14ACX-059-230
TXV
57,000
14.70
12.20
C33-60D
SL280UH135V60D
5053123
14ACX-059-230
TXV
56,500
15.00
12.20
C33-60D
SLP98UH135XV60D
5141551
14ACX-059-230
TXV
56,500
14.50
12.00
C33-60D
5053100
14ACX-059-230
TXV
58,000
15.50
12.70
C33-62C
EL180UH090E60C
5736414
14ACX-059-230
TXV
57,500
15.20
12.50
C33-62C
EL180UH110E60C
5738231
14ACX-059-230
TXV
57,500
14.70
12.20
C33-62C
EL180UH110XE60C
5739178
14ACX-059-230
TXV
58,000
15.40
12.50
C33-62C
EL195UH110XE60C
5053222
14ACX-059-230
TXV
58,000
15.40
12.50
C33-62C
EL296UH110XE60C
5648040
14ACX-059-230
TXV
57,500
15.00
12.20
C33-62C
EL296UH110XV60C
5431229
14ACX-059-230
TXV
58,000
15.20
12.50
C33-62C
SL280UH090V60C
5053182
14ACX-059-230
TXV
58,000
14.70
12.20
C33-62C
SL280UH110V60C
5053183
14ACX-059-230
TXV
58,000
14.70
12.20
C33-62C
SL280UH110XV60C
5053184
14ACX-059-230
TXV
58,000
14.70
12.20
C33-62C
SLP98UH090XV60C
5141547
14ACX-059-230
TXV
57,500
15.00
12.20
C33-62C
SLP98UH110XV60C
5141548
14ACX-059-230
TXV
57,500
14.70
12.20
C33-62C
5053095
14ACX-059-230
TXV
57,500
15.10
12.50
C33-62D
EL180UH135E60D
5746023
14ACX-059-230
TXV
57,500
14.50
12.20
C33-62D
EL195UH135XE60D
5053245
14ACX-059-230
TXV
57,500
14.50
12.20
C33-62D
EL296UH135XE60D
5648053
14ACX-059-230
TXV
57,500
15.00
12.50
C33-62D
EL296UH135XV60D
5433293
14ACX-059-230
TXV
57,000
15.50
12.70
C33-62D
SL280UH135V60D
5053188
14ACX-059-230
TXV
57,000
14.50
12.00
C33-62D
5053096
NOTES:
TXV = Matched with Thermostatic Expansion Valve.
RFC = Matched with RFC metering device.
Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (
58M81
) for field installation. See furnace or air handler specifications to determine if relay is needed.
Also see Expansion Valve Kit Usage Table.