14ACX - 1.5 to 5 Ton Air Conditioner / Page 166
AHRI SYSTEM MATCHES - SOUTHWEST REGION - 018-024-030-036-042
NOTE - For the latest up-to-date system matches please visit the AHRI web site at
http://www.ahridirectory.org
Model
No.
Expansion
Device
Capacity SEER EER
Coil or
Air Handler
Furnace
AHRI
Reference
14ACX-036-230A
TXV
35,400
16.00
13.00
CH33-49
SLP98UH090XV36C
7513207
14ACX-036-230A
TXV
35,200
16.00
13.00
CH33-49
SLP98UH090XV48C
7513209
14ACX-036-230A
TXV
35,800
16.00
13.00
CH33-49
SLP98UH110XV60C
7513212
14ACX-036-230A
TXV
34,800
14.50
12.20
CH33-49
7513194
14ACX-036-230A
TXV
35,200
16.00
13.00
CH33-50/60C
EL180UH090E60C
7510580
14ACX-036-230A
TXV
35,200
16.00
13.00
CH33-50/60C
EL180UH110E60C
7510581
14ACX-036-230A
TXV
35,200
16.00
13.00
CH33-50/60C
EL180UH110XE60C
7510582
14ACX-036-230A
TXV
35,000
16.00
13.00
CH33-50/60C
EL195UH090XE48C
7510583
14ACX-036-230A
TXV
35,200
16.00
13.00
CH33-50/60C
EL195UH110XE60C
7510585
14ACX-036-230A
TXV
35,000
16.00
13.00
CH33-50/60C
EL296UH090XE48C
7510584
14ACX-036-230A
TXV
35,200
16.00
13.00
CH33-50/60C
EL296UH090XV36C
7510587
14ACX-036-230A
TXV
35,000
16.00
13.00
CH33-50/60C
EL296UH090XV48C
7510589
14ACX-036-230A
TXV
35,200
16.00
13.00
CH33-50/60C
EL296UH110XE60C
7510586
14ACX-036-230A
TXV
35,200
16.00
13.00
CH33-50/60C
EL296UH110XV48C
7510591
14ACX-036-230A
TXV
35,600
16.00
13.00
CH33-50/60C
EL296UH110XV60C
7510592
14ACX-036-230A
TXV
35,600
16.00
13.00
CH33-50/60C
SL280UH090V60C
7510576
14ACX-036-230A
TXV
35,600
16.00
13.00
CH33-50/60C
SL280UH090XV60C
7510577
14ACX-036-230A
TXV
35,600
16.00
13.00
CH33-50/60C
SL280UH110V60C
7510578
14ACX-036-230A
TXV
35,600
16.00
13.00
CH33-50/60C
SL280UH110XV60C
7510579
14ACX-036-230A
TXV
35,200
16.00
13.00
CH33-50/60C
SLP98UH090XV36C
7510588
14ACX-036-230A
TXV
35,000
16.00
13.00
CH33-50/60C
SLP98UH090XV48C
7510590
14ACX-036-230A
TXV
35,600
16.00
13.00
CH33-50/60C
SLP98UH110XV60C
7510593
14ACX-036-230A
TXV
34,600
14.50
12.20
CH33-50/60C
7510595
14ACX-036-230A
TXV
34,000
15.00
12.50
CH35-30A
EL180UH045E36A
7510598
14ACX-036-230A
TXV
34,000
15.00
12.50
CH35-30A
EL180UH045XE36A
7510599
14ACX-036-230A
TXV
34,200
15.10
12.50
CH35-30A
SL280UH070V36A
7510596
14ACX-036-230A
TXV
34,200
15.10
12.50
CH35-30A
SL280UH070XV36A
7510597
14ACX-036-230A
TXV
34,800
15.10
12.50
CH35-30B
EL180UH070E36B
7510605
14ACX-036-230A
TXV
34,800
15.10
12.50
CH35-30B
EL180UH070XE36B
7510606
14ACX-036-230A
TXV
34,800
16.00
13.00
CH35-30B
EL180UH090E48B
7510607
14ACX-036-230A
TXV
34,800
16.00
13.00
CH35-30B
EL180UH090XE48B
7510608
14ACX-036-230A
TXV
34,400
14.50
12.20
CH35-30B
EL195UH045XE36B
7510609
14ACX-036-230A
TXV
34,400
15.00
12.50
CH35-30B
EL195UH070XE36B
7510611
14ACX-036-230A
TXV
34,400
14.50
12.20
CH35-30B
EL296UH045XE36B
7510610
14ACX-036-230A
TXV
34,600
15.10
12.50
CH35-30B
EL296UH045XV36B
7510613
14ACX-036-230A
TXV
34,400
15.00
12.50
CH35-30B
EL296UH070XE36B
7510612
14ACX-036-230A
TXV
34,600
15.10
12.50
CH35-30B
EL296UH070XV36B
7510614
14ACX-036-230A
TXV
34,800
16.00
13.00
CH35-30B
SL280UH090V36B
7510602
14ACX-036-230A
TXV
34,800
15.50
12.50
CH35-30B
SL280UH090V48B
7510603
14ACX-036-230A
TXV
34,800
15.50
12.50
CH35-30B
SL280UH090XV48B
7510604
14ACX-036-230A
TXV
34,600
15.10
12.50
CH35-30B
SLP98UH070XV36B
7510615
14ACX-036-230A
TXV
34,200
14.50
12.20
CH35-30B
7510601
14ACX-036-230A
TXV
33,000
14.50
12.20
CH35-36A
EL180UH045E36A
7510618
14ACX-036-230A
TXV
33,000
14.50
12.20
CH35-36A
EL180UH045XE36A
7510619
14ACX-036-230A
TXV
33,200
14.50
12.20
CH35-36A
SL280UH070V36A
7510616
14ACX-036-230A
TXV
33,200
14.50
12.20
CH35-36A
SL280UH070XV36A
7510617
14ACX-036-230A
TXV
33,400
15.50
12.50
CH35-36B
EL180UH070E36B
7510624
14ACX-036-230A
TXV
33,400
15.50
12.50
CH35-36B
EL180UH070XE36B
7510625
14ACX-036-230A
TXV
33,400
15.10
12.50
CH35-36B
EL180UH090E48B
7510626
NOTES:
TXV = Matched with Thermostatic Expansion Valve.
RFC = Matched with RFC metering device.
Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (
58M81
) for field installation. See furnace or air handler specifications to determine if relay is needed.
Also see Expansion Valve Kit Usage Table.