14ACX - 1.5 to 5 Ton Air Conditioner / Page 193
AHRI SYSTEM MATCHES - SOUTHWEST REGION - 018-024-030-036-042
NOTE - For the latest up-to-date system matches please visit the AHRI web site at
http://www.ahridirectory.org
Model
No.
Expansion
Device
Capacity SEER EER
Coil or
Air Handler
Furnace
AHRI
Reference
14ACX-042-230A
TXV
42,000
16.00
13.00
CX35-60C
EL296UH110XE60C
8267918
14ACX-042-230A
TXV
42,000
16.00
13.00
CX35-60C
EL296UH110XV60C
8267919
14ACX-042-230A
TXV
42,000
16.00
13.00
CX35-60C
SL280UH090V60C
8267920
14ACX-042-230A
TXV
42,000
16.00
13.00
CX35-60C
SL280UH090XV60C
8267909
14ACX-042-230A
TXV
42,000
16.00
13.00
CX35-60C
SL280UH110V60C
8267910
14ACX-042-230A
TXV
42,000
16.00
13.00
CX35-60C
SL280UH110XV60C
8267911
14ACX-042-230A
TXV
42,000
15.50
12.50
CX35-60C
SLP98UH090XV36C
8267912
14ACX-042-230A
TXV
42,000
16.00
13.00
CX35-60C
SLP98UH090XV48C
8267913
14ACX-042-230A
TXV
42,000
15.50
12.50
CX35-60C
SLP98UH090XV60C
8267914
14ACX-042-230A
TXV
42,000
16.00
13.00
CX35-60C
SLP98UH110XV60C
8267908
14ACX-042-230A
TXV
42,000
16.00
13.00
CX35-60D
EL180UH135E60D
8267928
14ACX-042-230A
TXV
42,000
15.50
12.50
CX35-60D
EL195UH135XE60D
8267929
14ACX-042-230A
TXV
42,000
15.50
12.50
CX35-60D
EL296UH135XE60D
8267930
14ACX-042-230A
TXV
42,000
16.00
13.00
CX35-60D
SL280UH135V60D
8267931
14ACX-042-230A
TXV
41,500
14.50
12.20
CX35-60D
8267927
NOTES:
TXV = Matched with Thermostatic Expansion Valve.
RFC = Matched with RFC metering device.
Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (
58M81
) for field installation. See furnace or air handler specifications to determine if relay is needed.
Also see Expansion Valve Kit Usage Table.