14ACX - 1.5 to 5 Ton Air Conditioner / Page 6
SPECIFICATIONS
General
Data
Model No.
All Regions
- - -
- - -
- - -
- - -
14ACX-041
North / South Regions 14ACXS018 14ACXS024 14ACXS030 14ACXS036
- - -
Southwest Region 14ACX-018
14ACX-024
14ACX-030
14ACX-036
- - -
Nominal Tonnage
1.5
2
2.5
3
3.5
Connections
(sweat)
Liquid line o.d. - in.
3/8
3/8
3/8
3/8
3/8
Suction line o.d. - in.
3/4
3/4
3/4
7/8
7/8
1
Refrigerant (R-410A) furnished
4 lbs. 13 oz.
5 lbs. 6 oz.
6 lbs. 11 oz.
6 lbs. 11 oz.
10 lbs. 1 oz.
Outdoor
Coil
Net face area
sq. ft.
Outer coil
13.22
16
21
21
21
Inner coil
- - -
- - -
- - -
- - -
20.25
Tube diameter - in.
5/16
5/16
5/16
5/16
5/16
Number of rows
1
1
1
1
2
Fins per inch
26
26
26
26
22
Outdoor
Fan
Diameter - in.
18
22
22
22
22
Number of blades
3
3
3
3
4
Motor hp
1/10
1/6
1/6
1/6
1/4
Cfm
2290
3160
3160
3160
3600
Rpm
1075
825
825
825
825
Watts
160
215
215
215
310
Shipping Data - lbs. 1 package
138
158
171
177
209
ELECTRICAL DATA
Line voltage data - 60 hz - 1ph
208/230V
208/230V
208/230V
208/230V
208/230V
2
Maximum overcurrent protection (amps)
20
25
25
30
35
3
Minimum circuit ampacity
12.4
15.0
17.1
18.6
22.6
Compressor
Rated load amps
9.4
11.2
12.9
14.1
16.7
Locked rotor amps
56.6
60.8
64
77
79
Power factor
0.96
0.97
0.98
0.98
0.97
Condenser
Fan Motor
Full load amps
0.7
1.0
1.0
1.0
1.7
Locked rotor amps
1.3
1.9
1.9
1.9
3.2
OPTIONAL ACCESSORIES - ORDER SEPARATELY
Compressor Crankcase Heater
93M04
•
•
•
•
Factory
•
Compressor Hard Start Kit
10J42
•
•
88M91
•
•
•
Compressor Low Ambient Cut-Off Switch
45F08
•
•
•
•
•
Compressor Sound Cover
27W55
•
•
•
•
27W56
•
Compressor Time-Off Control
47J27
•
•
•
•
•
Freezestat
3/8 in. tubing
93G35
•
•
•
•
•
5/8 in. tubing
50A93
•
•
•
•
•
Indoor Blower Off Delay Relay
58M81
•
•
•
•
•
Loss of Charge Switch Kit
84M23
•
•
•
•
•
4
Low Ambient Kit (Fan Cycling)
34M72
•
•
•
•
•
Mounting Base
69J06
•
69J07
•
•
•
•
Refrigerant Line
Sets
L15-41-20, L15-41-30,
L15-41-40, L15-41-50
•
•
•
L15-65-30, L15-65-40,
L15-65-50
•
•
Unit Stand-Off Kit
94J45
•
•
•
•
•
NOTE - Extremes of operating range are plus 10% and minus 5% of line voltage.
1
Refrigerant charge sufficient for 15 ft. length of refrigerant lines. For longer line set requirements see the Installation Instructions for information about line set length and
additional refrigerant charge required.
2
HACR type circuit breaker or fuse.
3
Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements.
4
Crankcase Heater and Freezestat are recommended with Low Ambient Kit.