14ACX - 1.5 to 5 Ton Air Conditioner / Page 92
AHRI SYSTEM MATCHES - NORTH / SOUTH REGION - S018-S024-S030-S036-S042
NOTE - For the latest up-to-date system matches please visit the AHRI web site at
http://www.ahridirectory.org
Model
No.
Expansion
Device
Capacity SEER EER
Coil or
Air Handler
Furnace
AHRI
Reference
14ACXS036-230A
TXV
33,000
14.50
12.20
CH33-36A
EL180UH045E36A
7782657
14ACXS036-230A
TXV
33,000
14.50
12.20
CH33-36A
EL180UH045XE36A
7626478
14ACXS036-230A
TXV
33,200
14.50
12.20
CH33-36A
SL280UH070V36A
7782656
14ACXS036-230A
TXV
33,200
14.50
12.20
CH33-36A
SL280UH070XV36A
7626475
14ACXS036-230A
TXV
33,400
15.50
12.50
CH33-36B
EL180UH070E36B
7782660
14ACXS036-230A
TXV
33,400
15.50
12.50
CH33-36B
EL180UH070XE36B
7626487
14ACXS036-230A
TXV
33,400
15.10
12.50
CH33-36B
EL180UH090E48B
7782661
14ACXS036-230A
TXV
33,400
15.10
12.50
CH33-36B
EL180UH090XE48B
7626490
14ACXS036-230A
TXV
33,000
15.00
12.50
CH33-36B
EL195UH045XE36B
7782662
14ACXS036-230A
TXV
33,200
15.00
12.50
CH33-36B
EL195UH070XE36B
7782663
14ACXS036-230A
TXV
33,000
15.00
12.50
CH33-36B
EL296UH045XE36B
7626493
14ACXS036-230A
TXV
33,400
14.50
12.20
CH33-36B
EL296UH045XV36B
7628362
14ACXS036-230A
TXV
33,200
15.00
12.50
CH33-36B
EL296UH070XE36B
7626496
14ACXS036-230A
TXV
33,400
15.00
12.50
CH33-36B
EL296UH070XV36B
7782664
14ACXS036-230A
TXV
33,400
15.50
12.50
CH33-36B
SL280UH090V36B
7626481
14ACXS036-230A
TXV
33,600
15.50
12.50
CH33-36B
SL280UH090V48B
7782659
14ACXS036-230A
TXV
33,600
15.50
12.50
CH33-36B
SL280UH090XV48B
7626484
14ACXS036-230A
TXV
33,400
15.00
12.50
CH33-36B
SLP98UH070XV36B
7626499
14ACXS036-230A
TXV
33,000
14.00
11.50
CH33-36B
7782658
14ACXS036-230A
TXV
33,800
15.50
12.50
CH33-36C
EL180UH090E60C
7626505
14ACXS036-230A
TXV
33,800
15.50
12.50
CH33-36C
EL180UH110E60C
7782667
14ACXS036-230A
TXV
33,800
15.50
12.50
CH33-36C
EL180UH110XE60C
7626508
14ACXS036-230A
TXV
33,600
15.10
12.50
CH33-36C
EL195UH090XE48C
7782668
14ACXS036-230A
TXV
34,000
15.50
12.50
CH33-36C
EL195UH110XE60C
7782669
14ACXS036-230A
TXV
33,600
15.10
12.50
CH33-36C
EL296UH090XE48C
7626511
14ACXS036-230A
TXV
34,000
15.50
12.50
CH33-36C
EL296UH090XV36C
7782670
14ACXS036-230A
TXV
33,800
15.50
12.50
CH33-36C
EL296UH090XV48C
7782671
14ACXS036-230A
TXV
34,000
15.50
12.50
CH33-36C
EL296UH110XE60C
7626514
14ACXS036-230A
TXV
34,000
15.50
12.50
CH33-36C
EL296UH110XV48C
7782672
14ACXS036-230A
TXV
34,200
15.50
12.50
CH33-36C
EL296UH110XV60C
7626523
14ACXS036-230A
TXV
34,400
15.50
12.50
CH33-36C
SL280UH090V60C
7783180
14ACXS036-230A
TXV
34,400
15.50
12.50
CH33-36C
SL280UH090XV60C
7628365
14ACXS036-230A
TXV
34,200
15.50
12.50
CH33-36C
SL280UH110V60C
7626502
14ACXS036-230A
TXV
34,200
15.50
12.50
CH33-36C
SL280UH110XV60C
7782666
14ACXS036-230A
TXV
34,000
15.50
12.50
CH33-36C
SLP98UH090XV36C
7626517
14ACXS036-230A
TXV
33,800
15.50
12.50
CH33-36C
SLP98UH090XV48C
7626520
14ACXS036-230A
TXV
34,200
15.50
12.50
CH33-36C
SLP98UH110XV60C
7782673
14ACXS036-230A
TXV
33,400
14.25
11.50
CH33-36C
7782665
14ACXS036-230A
TXV
34,200
15.00
12.50
CH33-42B
EL180UH070E36B
7628372
14ACXS036-230A
TXV
34,200
15.00
12.50
CH33-42B
EL180UH070XE36B
7628375
14ACXS036-230A
TXV
34,200
15.50
12.50
CH33-42B
EL180UH090E48B
7628377
14ACXS036-230A
TXV
34,200
15.50
12.50
CH33-42B
EL180UH090XE48B
7628380
14ACXS036-230A
TXV
34,000
14.50
12.20
CH33-42B
EL195UH045XE36B
7628383
14ACXS036-230A
TXV
34,000
15.10
12.50
CH33-42B
EL195UH070XE36B
7628388
14ACXS036-230A
TXV
34,000
14.50
12.20
CH33-42B
EL296UH045XE36B
7628385
14ACXS036-230A
TXV
34,200
15.00
12.50
CH33-42B
EL296UH045XV36B
7783184
14ACXS036-230A
TXV
34,000
15.10
12.50
CH33-42B
EL296UH070XE36B
7628390
14ACXS036-230A
TXV
34,200
15.10
12.50
CH33-42B
EL296UH070XV36B
7628393
14ACXS036-230A
TXV
34,400
15.50
12.50
CH33-42B
SL280UH090V36B
7783182
NOTES:
TXV = Matched with Thermostatic Expansion Valve.
RFC = Matched with RFC metering device.
Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (
58M81
) for field installation. See furnace or air handler specifications to determine if relay is needed.
Also see Expansion Valve Kit Usage Table.