14ACX - 1.5 to 5 Ton Air Conditioner / Page 15
AHRI SYSTEM MATCHES - ALL REGIONS - 041-047-048-059-060
NOTE - For the latest up-to-date system matches please visit the AHRI web site at
http://www.ahridirectory.org
Model
No.
Expansion
Device
Capacity SEER EER
Coil or
Air Handler
Furnace
AHRI
Reference
14ACX-041-230
TXV
40,000
16.00
13.00
C33-62C
EL180UH110XE60C
5738916
14ACX-041-230
TXV
40,000
16.00
13.50
C33-62C
EL195UH090XE48C
4693854
14ACX-041-230
TXV
40,500
16.00
13.50
C33-62C
EL195UH110XE60C
4693868
14ACX-041-230
TXV
40,000
16.00
13.50
C33-62C
EL296UH090XE48C
5647239
14ACX-041-230
TXV
40,500
16.00
13.50
C33-62C
EL296UH110XE60C
5647253
14ACX-041-230
TXV
40,000
16.00
13.00
C33-62C
SLP98UH090XV48C
5767289
14ACX-041-230
TXV
38,500
15.50
12.50
C35-36B
EL180UH090E48B
8267933
14ACX-041-230
TXV
38,500
15.50
12.50
C35-36B
EL180UH090XE48B
8267932
14ACX-041-230
TXV
38,500
15.50
12.50
C35-48B
EL180UH090E48B
8267940
14ACX-041-230
TXV
38,500
15.50
12.50
C35-48B
EL180UH090XE48B
8267938
14ACX-041-230
TXV
37,800
14.50
12.20
C35-48B
8267934
14ACX-041-230
TXV
38,500
16.00
13.00
C35-48C
EL180UH090E60C
8267939
14ACX-041-230
TXV
38,500
16.00
13.00
C35-48C
EL180UH110E60C
8267941
14ACX-041-230
TXV
38,500
16.00
13.00
C35-48C
EL180UH110XE60C
8267942
14ACX-041-230
TXV
38,500
15.50
12.50
C35-48C
EL195UH090XE48C
8267946
14ACX-041-230
TXV
38,500
15.50
12.50
C35-48C
EL195UH110XE60C
8267945
14ACX-041-230
TXV
38,500
15.50
12.50
C35-48C
EL296UH090XE48C
8267944
14ACX-041-230
TXV
38,500
15.50
12.50
C35-48C
EL296UH110XE60C
8267943
14ACX-041-230
TXV
39,000
16.00
13.00
C35-48C
SL280UH090V60C
8267936
14ACX-041-230
TXV
39,000
16.00
13.00
C35-48C
SL280UH090XV60C
8267947
14ACX-041-230
TXV
38,500
15.50
12.50
C35-48C
SL280UH110V60C
8267937
14ACX-041-230
TXV
38,500
15.50
12.50
C35-48C
SL280UH110XV60C
8267948
14ACX-041-230
TXV
37,800
14.50
12.20
C35-48C
8267935
14ACX-041-230
TXV
39,000
16.00
13.00
C35-49C
EL180UH090E60C
8267950
14ACX-041-230
TXV
39,000
16.00
13.00
C35-49C
EL180UH110E60C
8267951
14ACX-041-230
TXV
39,000
16.00
13.00
C35-49C
EL180UH110XE60C
8267952
14ACX-041-230
TXV
38,500
16.00
13.00
C35-49C
EL195UH090XE48C
8267956
14ACX-041-230
TXV
39,000
15.50
12.50
C35-49C
EL195UH110XE60C
8267955
14ACX-041-230
TXV
38,500
16.00
13.00
C35-49C
EL296UH090XE48C
8267954
14ACX-041-230
TXV
39,000
15.50
12.50
C35-49C
EL296UH110XE60C
8267953
14ACX-041-230
TXV
38,500
14.70
12.50
C35-49C
8267949
14ACX-041-230
TXV
38,000
15.50
12.50
C35-50/60C
EL180UH090E60C
8267957
14ACX-041-230
TXV
38,000
15.50
12.50
C35-50/60C
EL180UH110E60C
8267958
14ACX-041-230
TXV
38,000
15.50
12.50
C35-50/60C
EL180UH110XE60C
8267959
14ACX-041-230
TXV
38,000
15.50
12.50
C35-50/60C
EL195UH090XE48C
8267963
14ACX-041-230
TXV
38,500
15.50
12.50
C35-50/60C
EL195UH110XE60C
8267962
14ACX-041-230
TXV
38,000
15.50
12.50
C35-50/60C
EL296UH090XE48C
8267961
14ACX-041-230
TXV
38,500
15.50
12.50
C35-50/60C
EL296UH110XE60C
8267960
14ACX-041-230
TXV
40,000
16.00
13.00
C35-60C
EL180UH090E60C
8267965
14ACX-041-230
TXV
40,000
16.00
13.00
C35-60C
EL180UH110E60C
8267966
14ACX-041-230
TXV
40,000
16.00
13.00
C35-60C
EL180UH110XE60C
8267967
14ACX-041-230
TXV
39,500
16.00
13.00
C35-60C
EL195UH090XE48C
8267971
14ACX-041-230
TXV
40,000
16.00
13.00
C35-60C
EL195UH110XE60C
8267970
14ACX-041-230
TXV
39,500
16.00
13.00
C35-60C
EL296UH090XE48C
8267969
14ACX-041-230
TXV
40,000
16.00
13.00
C35-60C
EL296UH110XE60C
8267968
14ACX-041-230
TXV
40,000
16.00
13.00
C35-60C
SLP98UH090XV48C
8267964
14ACX-041-230
TXV
38,000
14.50
12.50
CBX25UH-042
5732787
14ACX-041-230
TXV
39,500
15.20
13.00
CBX25UH-048
5732788
14ACX-041-230
TXV
39,000
16.00
13.50
CBX25UHV-042
6970129
NOTES:
TXV = Matched with Thermostatic Expansion Valve.
RFC = Matched with RFC metering device.
Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (
58M81
) for field installation. See furnace or air handler specifications to determine if relay is needed.
Also see Expansion Valve Kit Usage Table.