AHRI SYSTEM MATCHES - NORTH / SOUTH REGION - S018-S024-S030-S036-S042
NOTE - For the latest up-to-date system matches please visit the AHRI web site at
http://www.ahridirectory.org
Model
No.
Expansion
Device
Capacity SEER EER
Coil or
Air Handler
Furnace
AHRI
Reference
14ACXS030-230A
TXV
28,000
16.00
13.00
CH35-42C
SLP98UH090XV36C
7625882
14ACXS030-230A
TXV
28,000
14.50
12.20
CH35-42C
7625875
14ACXS030-230A
TXV
26,800
14.50
12.20
CR33-24A
EL180DF045E36A
7625884
14ACXS030-230A
TXV
26,800
14.25
12.20
CR33-24B
EL180DF070E36B
7625889
14ACXS030-230A
TXV
26,600
14.00
12.00
CR33-24B
EL180DF090E48B
7783229
14ACXS030-230A
TXV
26,600
14.25
12.20
CR33-24B
EL296DF045XV36B
7783151
14ACXS030-230A
TXV
26,600
14.00
12.00
CR33-24B
EL296DF070XV48B
7625887
14ACXS030-230A
TXV
26,600
14.25
12.20
CR33-24B
SL280DF090V48B
7625885
14ACXS030-230A
TXV
26,600
14.25
12.20
CR33-24B
SLP98DF070XV36B
7628270
14ACXS030-230A
TXV
28,000
15.10
12.50
CR33-30/36A
EL180DF045E36A
7625896
14ACXS030-230A
TXV
28,000
15.50
12.50
CR33-30/36A
SL280DF070V36A
7625895
14ACXS030-230A
TXV
28,000
14.25
12.00
CR33-30/36A
7625893
14ACXS030-230A
TXV
28,000
15.50
12.50
CR33-30/36B
EL180DF070E36B
7625904
14ACXS030-230A
TXV
28,000
15.50
12.50
CR33-30/36B
EL180DF090E48B
7625905
14ACXS030-230A
TXV
28,000
15.10
12.50
CR33-30/36B
EL195DF045XE36B
7625907
14ACXS030-230A
TXV
28,000
15.50
12.50
CR33-30/36B
EL195DF070XE48B
7625911
14ACXS030-230A
TXV
28,000
15.10
12.50
CR33-30/36B
EL296DF045XE36B
7625909
14ACXS030-230A
TXV
28,000
15.50
12.50
CR33-30/36B
EL296DF045XV36B
7625914
14ACXS030-230A
TXV
28,000
15.50
12.50
CR33-30/36B
EL296DF070XE48B
7625912
14ACXS030-230A
TXV
28,000
15.10
12.50
CR33-30/36B
EL296DF070XV48B
7625916
14ACXS030-230A
TXV
28,000
15.50
12.50
CR33-30/36B
SL280DF090V48B
7625902
14ACXS030-230A
TXV
28,000
15.50
12.50
CR33-30/36B
SLP98DF070XV36B
7625918
14ACXS030-230A
TXV
28,000
14.25
12.00
CR33-30/36B
7625900
14ACXS030-230A
TXV
28,000
16.00
13.00
CR33-30/36C
SLP98DF090XV36C
7625923
14ACXS030-230A
TXV
28,000
14.25
12.00
CR33-30/36C
7625921
14ACXS030-230A
TXV
28,000
15.10
12.50
CX34-25A
EL180UH045E36A
7625930
14ACXS030-230A
TXV
28,000
15.10
12.50
CX34-25A
EL180UH045XE36A
7625931
14ACXS030-230A
TXV
28,000
15.50
12.50
CX34-25A
SL280UH070V36A
7625926
14ACXS030-230A
TXV
28,000
15.50
12.50
CX34-25A
SL280UH070XV36A
7625928
14ACXS030-230A
TXV
27,600
14.00
12.00
CX34-25A
7625925
14ACXS030-230A
TXV
28,000
15.50
12.50
CX34-25B
EL180UH070E36B
7625940
14ACXS030-230A
TXV
28,000
15.50
12.50
CX34-25B
EL180UH070XE36B
7625941
14ACXS030-230A
TXV
27,800
15.50
12.50
CX34-25B
EL180UH090E48B
7625935
14ACXS030-230A
TXV
27,800
15.50
12.50
CX34-25B
EL180UH090XE48B
7625936
14ACXS030-230A
TXV
28,000
15.10
12.50
CX34-25B
EL195UH045XE36B
7625943
14ACXS030-230A
TXV
28,000
15.00
12.50
CX34-25B
EL195UH070XE36B
7625946
14ACXS030-230A
TXV
28,000
15.10
12.50
CX34-25B
EL296UH045XE36B
7625944
14ACXS030-230A
TXV
28,000
15.10
12.50
CX34-25B
EL296UH045XV36B
7625949
14ACXS030-230A
TXV
28,000
15.00
12.50
CX34-25B
EL296UH070XE36B
7625948
14ACXS030-230A
TXV
28,000
15.10
12.50
CX34-25B
EL296UH070XV36B
7625951
14ACXS030-230A
TXV
28,000
15.50
12.50
CX34-25B
SL280UH090V36B
7625938
14ACXS030-230A
TXV
28,000
15.10
12.50
CX34-25B
SLP98UH070XV36B
7625953
14ACXS030-230A
TXV
27,600
14.00
12.00
CX34-25B
7625933
14ACXS030-230A
TXV
27,400
15.00
12.50
CX34-30A
EL180UH045E36A
7782496
14ACXS030-230A
TXV
27,400
15.00
12.50
CX34-30A
EL180UH045XE36A
7625971
14ACXS030-230A
TXV
27,400
15.00
12.50
CX34-30A
SL280UH070V36A
7625965
14ACXS030-230A
TXV
27,400
15.00
12.50
CX34-30A
SL280UH070XV36A
7625968
14ACXS030-230A
TXV
27,400
15.10
12.50
CX34-30B
EL180UH070E36B
7782497
14ACXS030-230A
TXV
27,400
15.10
12.50
CX34-30B
EL180UH070XE36B
7625974
NOTES:
TXV = Matched with Thermostatic Expansion Valve.
RFC = Matched with RFC metering device.
Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (
58M81
) for field installation. See furnace or air handler specifications to determine if relay is needed.
Also see Expansion Valve Kit Usage Table.