14ACX - 1.5 to 5 Ton Air Conditioner / Page 36
AHRI SYSTEM MATCHES - ALL REGIONS - 041-047-048-059-060
NOTE - For the latest up-to-date system matches please visit the AHRI web site at
http://www.ahridirectory.org
Model
No.
Expansion
Device
Capacity SEER EER
Coil or
Air Handler
Furnace
AHRI
Reference
14ACX-048-230
TXV
46,500
14.00
11.70
CR33-48
EL296DF110XE60C
7486626
14ACX-048-230
TXV
46,500
14.25
11.70
CR33-48
SL280DF090V60C
7486628
14ACX-048-230
TXV
46,500
14.25
11.70
CR33-48
SL280DF110V60C
7486629
14ACX-048-230
TXV
47,500
14.25
12.00
CR33-50/60
EL180DF110E60C
7486634
14ACX-048-230
TXV
47,000
14.25
12.00
CR33-50/60
EL195DF110XE60C
7486630
14ACX-048-230
TXV
47,000
14.00
11.70
CR33-50/60
EL296DF090XV60C
7486632
14ACX-048-230
TXV
47,000
14.25
12.00
CR33-50/60
EL296DF110XE60C
7486631
14ACX-048-230
TXV
47,000
14.00
11.70
CR33-50/60
EL296DF110XV60C
7486633
14ACX-048-230
TXV
47,000
14.25
12.00
CR33-50/60
SL280DF090V60C
7486635
14ACX-048-230
TXV
47,000
14.50
12.00
CR33-50/60
SL280DF110V60C
7486636
14ACX-048-230
TXV
47,000
14.00
11.70
CR33-50/60
SLP98DF090XV48C
7486637
14ACX-048-230
TXV
47,000
14.00
11.70
CR33-50/60
SLP98DF090XV60C
7486638
14ACX-048-230
TXV
47,000
14.00
11.70
CR33-50/60
SLP98DF110XV60C
7486639
14ACX-048-230
TXV
48,000
14.25
12.00
CX34-43B
EL180UH090E48B
7486640
14ACX-048-230
TXV
48,000
14.25
12.00
CX34-43B
EL180UH090XE48B
7486641
14ACX-048-230
TXV
48,000
14.50
12.00
CX34-43C
EL180UH090E60C
7486650
14ACX-048-230
TXV
47,500
14.50
12.00
CX34-43C
EL180UH110E60C
7486651
14ACX-048-230
TXV
47,500
14.50
12.00
CX34-43C
EL180UH110XE60C
7486652
14ACX-048-230
TXV
48,000
14.50
12.00
CX34-43C
EL195UH090XE48C
7486642
14ACX-048-230
TXV
48,000
14.50
12.00
CX34-43C
EL195UH110XE60C
7486644
14ACX-048-230
TXV
48,000
14.50
12.00
CX34-43C
EL296UH090XE48C
7486643
14ACX-048-230
TXV
48,000
14.25
12.00
CX34-43C
EL296UH090XV48C
7486646
14ACX-048-230
TXV
48,000
14.25
12.00
CX34-43C
EL296UH090XV60C
7486647
14ACX-048-230
TXV
48,000
14.50
12.00
CX34-43C
EL296UH110XE60C
7486645
14ACX-048-230
TXV
48,000
14.50
12.00
CX34-43C
EL296UH110XV48C
7486648
14ACX-048-230
TXV
48,000
14.25
12.00
CX34-43C
EL296UH110XV60C
7486649
14ACX-048-230
TXV
48,000
14.50
12.00
CX34-43C
SL280UH090V60C
7486653
14ACX-048-230
TXV
48,000
14.50
12.00
CX34-43C
SL280UH090XV60C
7486654
14ACX-048-230
TXV
48,000
14.50
12.00
CX34-43C
SL280UH110V60C
7486655
14ACX-048-230
TXV
48,000
14.50
12.00
CX34-43C
SL280UH110XV60C
7486656
14ACX-048-230
TXV
48,000
14.25
12.00
CX34-43C
SLP98UH090XV48C
7486657
14ACX-048-230
TXV
48,000
14.25
12.00
CX34-43C
SLP98UH090XV60C
7486658
14ACX-048-230
TXV
48,000
14.25
12.00
CX34-43C
SLP98UH110XV60C
7486659
14ACX-048-230
TXV
47,000
14.00
11.70
CX34-44/48B
EL180UH090E48B
7486660
14ACX-048-230
TXV
47,000
14.00
11.70
CX34-44/48B
EL180UH090XE48B
7486661
14ACX-048-230
TXV
46,500
14.25
11.70
CX34-44/48C
EL180UH090E60C
7486668
14ACX-048-230
TXV
47,500
14.00
11.70
CX34-44/48C
EL180UH110E60C
7486669
14ACX-048-230
TXV
47,500
14.00
11.70
CX34-44/48C
EL180UH110XE60C
7486670
14ACX-048-230
TXV
46,500
14.00
11.70
CX34-44/48C
EL195UH090XE48C
7486662
14ACX-048-230
TXV
46,500
14.00
11.70
CX34-44/48C
EL195UH110XE60C
7486664
14ACX-048-230
TXV
46,500
14.00
11.70
CX34-44/48C
EL296UH090XE48C
7486663
14ACX-048-230
TXV
47,000
14.00
11.70
CX34-44/48C
EL296UH090XV48C
7486666
14ACX-048-230
TXV
46,500
14.00
11.70
CX34-44/48C
EL296UH110XE60C
7486665
14ACX-048-230
TXV
47,000
14.00
11.70
CX34-44/48C
EL296UH110XV48C
7486667
14ACX-048-230
TXV
47,000
14.25
11.70
CX34-44/48C
SL280UH090V60C
7486671
14ACX-048-230
TXV
47,000
14.25
11.70
CX34-44/48C
SL280UH090XV60C
7486672
14ACX-048-230
TXV
47,000
14.00
11.70
CX34-44/48C
SL280UH110V60C
7486673
14ACX-048-230
TXV
47,000
14.00
11.70
CX34-44/48C
SL280UH110XV60C
7486674
14ACX-048-230
TXV
47,000
14.00
11.70
CX34-44/48C
SLP98UH090XV48C
7486675
NOTES:
TXV = Matched with Thermostatic Expansion Valve.
RFC = Matched with RFC metering device.
Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (
58M81
) for field installation. See furnace or air handler specifications to determine if relay is needed.
Also see Expansion Valve Kit Usage Table.