14ACX - 1.5 to 5 Ton Air Conditioner / Page 124
AHRI SYSTEM MATCHES - NORTH / SOUTH REGION - S018-S024-S030-S036-S042
NOTE - For the latest up-to-date system matches please visit the AHRI web site at
http://www.ahridirectory.org
Model
No.
Expansion
Device
Capacity SEER EER
Coil or
Air Handler
Furnace
AHRI
Reference
14ACXS042-230A
TXV
41,500
14.50
12.20
CX35-60D
8258667
NOTES:
TXV = Matched with Thermostatic Expansion Valve.
RFC = Matched with RFC metering device.
Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (
58M81
) for field installation. See furnace or air handler specifications to determine if relay is needed.
Also see Expansion Valve Kit Usage Table.