14ACX - 1.5 to 5 Ton Air Conditioner / Page 157
AHRI SYSTEM MATCHES - SOUTHWEST REGION - 018-024-030-036-042
NOTE - For the latest up-to-date system matches please visit the AHRI web site at
http://www.ahridirectory.org
Model
No.
Expansion
Device
Capacity SEER EER
Coil or
Air Handler
Furnace
AHRI
Reference
14ACX-036-230A
TXV
34,800
15.50
12.50
C33-43B
EL296UH045XV36B
7510322
14ACX-036-230A
TXV
34,600
15.10
12.50
C33-43B
EL296UH070XE36B
7510321
14ACX-036-230A
TXV
34,800
15.50
12.50
C33-43B
EL296UH070XV36B
7510323
14ACX-036-230A
TXV
34,800
16.00
13.00
C33-43B
SL280UH090V36B
7510311
14ACX-036-230A
TXV
35,000
16.00
13.00
C33-43B
SL280UH090V48B
7510312
14ACX-036-230A
TXV
35,000
16.00
13.00
C33-43B
SL280UH090XV48B
7510313
14ACX-036-230A
TXV
34,800
15.50
12.50
C33-43B
SLP98UH070XV36B
7510324
14ACX-036-230A
TXV
34,400
14.50
12.20
C33-43B
7510310
14ACX-036-230A
TXV
34,800
16.00
13.00
C33-43C
EL180UH090E60C
7510330
14ACX-036-230A
TXV
34,800
16.00
13.00
C33-43C
EL180UH110E60C
7510331
14ACX-036-230A
TXV
34,800
16.00
13.00
C33-43C
EL180UH110XE60C
7510332
14ACX-036-230A
TXV
34,600
15.50
12.50
C33-43C
EL195UH090XE48C
7510333
14ACX-036-230A
TXV
34,800
16.00
13.00
C33-43C
EL195UH110XE60C
7510335
14ACX-036-230A
TXV
34,600
15.50
12.50
C33-43C
EL296UH090XE48C
7510334
14ACX-036-230A
TXV
34,800
16.00
13.00
C33-43C
EL296UH090XV36C
7510337
14ACX-036-230A
TXV
34,800
16.00
13.00
C33-43C
EL296UH090XV48C
7510339
14ACX-036-230A
TXV
34,800
16.00
13.00
C33-43C
EL296UH110XE60C
7510336
14ACX-036-230A
TXV
35,000
16.00
13.00
C33-43C
EL296UH110XV48C
7510341
14ACX-036-230A
TXV
35,200
16.00
13.00
C33-43C
EL296UH110XV60C
7510342
14ACX-036-230A
TXV
35,400
16.00
13.00
C33-43C
SL280UH090V60C
7510326
14ACX-036-230A
TXV
35,400
16.00
13.00
C33-43C
SL280UH090XV60C
7510327
14ACX-036-230A
TXV
35,200
16.00
13.00
C33-43C
SL280UH110V60C
7510328
14ACX-036-230A
TXV
35,200
16.00
13.00
C33-43C
SL280UH110XV60C
7510329
14ACX-036-230A
TXV
34,800
16.00
13.00
C33-43C
SLP98UH090XV36C
7510338
14ACX-036-230A
TXV
34,800
16.00
13.00
C33-43C
SLP98UH090XV48C
7510340
14ACX-036-230A
TXV
35,200
16.00
13.00
C33-43C
SLP98UH110XV60C
7510343
14ACX-036-230A
TXV
34,400
14.50
12.20
C33-43C
7510325
14ACX-036-230A
TXV
34,200
16.00
13.00
C33-48B
EL180UH070E36B
7510348
14ACX-036-230A
TXV
34,200
16.00
13.00
C33-48B
EL180UH070XE36B
7510349
14ACX-036-230A
TXV
34,200
15.50
12.50
C33-48B
EL180UH090E48B
7510350
14ACX-036-230A
TXV
34,200
15.50
12.50
C33-48B
EL180UH090XE48B
7510351
14ACX-036-230A
TXV
33,800
15.10
12.50
C33-48B
EL195UH045XE36B
7510352
14ACX-036-230A
TXV
34,200
15.00
12.50
C33-48B
EL195UH070XE36B
7510354
14ACX-036-230A
TXV
33,800
15.10
12.50
C33-48B
EL296UH045XE36B
7510353
14ACX-036-230A
TXV
34,200
15.10
12.50
C33-48B
EL296UH045XV36B
7510356
14ACX-036-230A
TXV
34,200
15.00
12.50
C33-48B
EL296UH070XE36B
7510355
14ACX-036-230A
TXV
34,200
15.10
12.50
C33-48B
EL296UH070XV36B
7510357
14ACX-036-230A
TXV
34,400
16.00
13.00
C33-48B
SL280UH090V36B
7510345
14ACX-036-230A
TXV
34,400
16.00
13.00
C33-48B
SL280UH090V48B
7510346
14ACX-036-230A
TXV
34,400
16.00
13.00
C33-48B
SL280UH090XV48B
7510347
14ACX-036-230A
TXV
34,000
15.10
12.50
C33-48B
SLP98UH070XV36B
7510358
14ACX-036-230A
TXV
34,200
15.10
12.50
C33-48C
EL195UH090XE48C
7510360
14ACX-036-230A
TXV
34,400
15.50
12.50
C33-48C
EL195UH110XE60C
7510362
14ACX-036-230A
TXV
34,200
15.10
12.50
C33-48C
EL296UH090XE48C
7510361
14ACX-036-230A
TXV
34,400
15.50
12.50
C33-48C
EL296UH090XV36C
7510364
14ACX-036-230A
TXV
34,400
15.50
12.50
C33-48C
EL296UH090XV48C
7510366
14ACX-036-230A
TXV
34,400
15.50
12.50
C33-48C
EL296UH110XE60C
7510363
14ACX-036-230A
TXV
34,400
15.50
12.50
C33-48C
SLP98UH090XV36C
7510365
14ACX-036-230A
TXV
34,400
15.50
12.50
C33-48C
SLP98UH090XV48C
7510367
NOTES:
TXV = Matched with Thermostatic Expansion Valve.
RFC = Matched with RFC metering device.
Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (
58M81
) for field installation. See furnace or air handler specifications to determine if relay is needed.
Also see Expansion Valve Kit Usage Table.