Page 32
Transport/Start up
Group 5
Release R1.12 en
JET2 neo
5.3 Installation
For adaption to the production line several works have to be carried out and operating
parameters have to be set before start of operation.
5.3.1 Mains supply
Mains supply!
The device does not have a mains switch and should be only connected
to an easy accessible socket close to the installation location!
The LEIBINGER JET2neo should be connected to AC voltage 100-240 V AC, 50-60 Hz
with an appropriate plug.
The socket should be provided with a clear designation
(e.g.: JET2neo).
After connecting to the mains power supply the initialization of the device will be carried
out automatically. After this process the JET2neo is ready for operation.
You will find further information regarding the initialization in the
chapter
Initialization of device
!
5.3.2
Grounding
(Potential
equalization)
Grounding (Potential equalization)!
In case of a non existing grounding or that the grounding of the printer is
not carried out properly, this could cause serious injury or death and it can
also cause malfunctions or damages at the printer!
These dangers or demolitions can happen for example because of
electrostatic discharge (ESD) or potential difference.
Specially for countries without existing protected earth connection, there is a special
grounding point located at the side of the printer.
This threaded socket must be connected to ground if there is no ground pin in the mains
socket/plug.
The threaded case is sealed inwards and thus IP 65 conform. With a screw and a ring
terminal (cable lug) the grounding can be fixed easily.
Summary of Contents for JET2 neo
Page 1: ...Manual LEIBINGER JET2NEO Release 1 12en ...
Page 2: ......
Page 11: ...Group 1 Table of contents Page 9 JET2 neo Release R1 12 en ...
Page 12: ......
Page 21: ...Group 2 Safety Page 19 JET2 neo Release R1 12 en 2 4 Safety sticker Figure 1 Safety sticker ...
Page 276: ...Page 274 Appendix Group 12 Release R1 12 en JET2 neo Interface X4 Inputs Interface X3 Outputs ...