Group 10
Equipping/Maintenance
Page 259
JET2 neo
Release R1.12 en
10. Equipping/Maintenance
10.1 Equipping
Caution
– Danger of explosion!
Before filling the device with the consumables, measures for the electrostatic discharge
have to be made!
The operator can carry out a discharge either by the direct touching of the LJ2 NEO- cabinet
or by standing with the appropriate ESD-shoes on an grounded surface!
Dangerous material in the machine!
Danger of serious damage through burns, skin irriation and poisoning! Read the safety leaflets
and the regulations on personal safety equipment!
10.1.1 Re-filling process and TAG-reader
10.1.1.1 General
The two reservoir tanks are always unpressurized and can be opened in every device
condition
– also during the production.
The reservoir tanks and the sealing cap are color-coded and labelled to avoid any
mistakes in filling. Additionally the sealing caps are marked with the ink-no. or solvent-no.
which are admissible for the device.
For correct handling the LEIBINGER re-filling system allows an odor- and splash free
refilling of the consumables.
Inks and solvent made by Paul Leibinger GmbH & Co. KG are identified by TAGs. The
TAG is located below the label of each re-fill bottle
(see also afterimage). The printer is
equipped with a TAG reader to read the TAG codes.
Summary of Contents for JET2 neo
Page 1: ...Manual LEIBINGER JET2NEO Release 1 12en ...
Page 2: ......
Page 11: ...Group 1 Table of contents Page 9 JET2 neo Release R1 12 en ...
Page 12: ......
Page 21: ...Group 2 Safety Page 19 JET2 neo Release R1 12 en 2 4 Safety sticker Figure 1 Safety sticker ...
Page 276: ...Page 274 Appendix Group 12 Release R1 12 en JET2 neo Interface X4 Inputs Interface X3 Outputs ...