User Manual for ELP Servo
www.leadshine.com
133
Pr8.11
Homing position H
0X600B
Pr8.12
Homing position L
0X600C
Pr8.13
Homing stop position H
0X600D
Pr8.14
Homing stop position L
0X600E
Pr8.15
Homing high speed
0X600F
Pr8.16
Homing low speed
0X6010
Pr8.17
Homing acceleration
0X6011
Pr8.18
Homing deceleration
0X6012
Pr8.19
Holding time of homing
with torque detect
0X6013
Pr8.20
Torque value of homing
with torque detect
0X6014
Pr8.21
Overpass distance setting
while homing
0X6015
Pr8.22
Position limit e-stop speed
0X6016
Pr8.23
E-stop speed
0X6017
Pr8.26
IO combined trigger mode
0
:
invalid
,
CTRG signal trigger
1
:
valid after homing process finished
2
:
valid without homing process
0X601A
Pr8.27
IO combined filtering
0X601B
Pr8.28
Output value of S code
0X601C
Pr8.29
PR alarm
=0x100
:
Homing overpass limit switch
=0x101
:
Homing process not complete and stop urgently
;
=0x20x
:
Path X overpass the limit switch
0X601D
Pr8.39
JOG speed
0X6027
Pr8.40
Acceleration of JOG
0X6028
Pr8.41
Deceleration of JOG
0X6029
Pr8.42
Command position H
0X602A
Pr8.43
Command position L
0X602B
Pr8.44
Motor position H
0X602C
Pr8.45
Motor position L
0X602D
9.2.2 9th parameters specification
Parameters
Name
Definition
485
address
Pr9.00
Path0 Mode
The motion mode of Path0 motion
Bit0-3
:
TYPE:
0 No Action
1 position mode
2 velocity mode
3 homing
0X6200