User Manual Of ELP AC Servo
104
www.leadshine.com
Repower
-
Select the condition to output the positioning complete signal (INP1).
Setup
value
Action of positioning complete signal
0
The signal will turn on when the positional deviation is smaller than
Pr4.31 [positioning complete range].
1
The signal will turn on when there is no position command and
position deviation is smaller than Pr4.31 [positioning complete range].
2
The signal will turn on when there is no position command, the
zero-speed detection signal is ON and the positional deviation is
smaller than Pr4.31 [positioning complete range].
3
The signal will turn on when there is no position command and the
positional deviation is smaller than Pr4.31 [positioning complete
range].Then holds “ON” states until the next position command is
entered. Subsequently, ON state is maintained until Pr4.33 INP hold
time has elapsed. After the hold time, INP output will be turned
ON/OFF according to the coming positional command or condition of
the positional deviation.
Pr4.33
Name
INP hold time
Mode
P
Range
0~30000
Unit
1ms
Default
0
Data Type
16bit
Access R/W
Address
0443H
Repower
-
Set up the hold time when Pr 4.32 positioning complete output setup=3
Setup value
State of Positioning complete signal
0
The hold time is maintained definitely, keeping ON state until
next positional command is received.
1-30000
ON state is maintained for setup time (ms)but switched to OFF
state as the positional command is received during hold time.
And the output port should be assigned for “INP”, for details of these parameters, refer to PA_410 – PA415.
Other setup for SI/SO function
For details of SI input function, refer to Pr4.00 – Pr4.09.
For details of SO output function, refer to Pr4.10 – Pr4.15.
8.2 Velocity Control
Notice :
Analog input for Torque/Velocity mode is only available for ELP-RS***Z
Pls do inspection before velocity control test run.
Table 8.3 Parameter Setup of Velocity Control
No
Parameter Name
input
Setup value
Unit
1
Pr0.01
Control mode setup
/
1
/
2
Pr3.12
Acceleration time setup
/
User-specified
millisecond
3
Pr3.13
Deceleration time setup
/
User-specified
millisecond
4
Pr3.14
Sigmoid acceleration/deceleration time
setup
/
User-specified
millisecond
5
Pr3.15
Zero speed clamping function select
/
1
/
6
Pr3.00
Velocity setup internal and external
switching
/
User-specified
/