User Manual Of ELP AC Servo
107
www.leadshine.com
Relevant parameters setup of velocity control mode
8.2.1 Velocity control by analog speed command
The analog speed command input voltage is converted to equivalent digital speed command. You can set the
filter to eliminate noise or adjust the offset.
Pr3.00
Name
Speed setup, Internal /External
switching
Mode
S
Range
0~3
Unit
—
Default
0
Data Type
16bit
Access
R/W
Address
0301H
Repower
-
This driver is equipped with internal speed setup function so that you can control the
speed with contact inputs only.
Setup value Speed setup method
0
Analog speed command(SPR)
1
Internal speed command 1st to 4th speed(PR3.04-PR3.07)
2
Internal speed command 1st to 3rd speed (PR3.04-PR3.06),
Analog speed command(SPR)
3
Internal speed command 1st to 8th speed (PR3.04-PR3.11)
<relationship between Pr3.00 Internal/External switching speed setup and the
internal command speed selection 1-3 and speed command to be selected>
Setup
value
selection 1
of internal
command
speed
(INTSPD1)
selection 2
of internal
command
speed
(INTSPD2)
selection 3
of internal
command
speed
(INTSPD3)
selection of Speed
command
1
OFF
OFF
NO effect
1st speed
ON
OFF
2nd speed
OFF
ON
3rd speed
ON
ON
4th speed
2
OFF
OFF
NO effect
1st speed
ON
OFF
2nd speed
OFF
ON
3rd speed
ON
ON
Analog speed command
3
The same as [Pr3.00=1]
OFF
1st to 4th speed
OFF
OFF
ON
5th speed
ON
OFF
ON
6th speed
OFF
ON
ON
7th speed
ON
ON
ON
8th speed
Pr3.01
Name
Speed command rotational
direction selection
Mode
S
Range
0~1
Unit
—
Default
0
Data Type
16bit
Access
R/W
Address
0303H
Repower
-